For the past 4 years, we have used highly efficient Medtronic electrodes (Nos. 6901 and 6907), with small surface areas, for cardiac pacemakers. We have found that chronic thresholds average 1.6 Ma. at a 1 msec. pulse duration, compared to 4.9 Ma. for the conventional Medtronic No. 5816 electrodes. These electrodes have been used in association with Medtronic Models 5961 and 5931, ventricular-inhibited and asynchronous pulse generators in which output current and voltage are fixed and pulse duration is variable. Drain from the generator battery is directly related to impulse duration and is reduced at shorter durations. The strength-duration curve of cardiac stimulation suggests and actual long-term pacing has been achieved at an average of 0.2 to 0.3 msec., rather than the conventional 1.0 msec. Drain from the battery is one fourth that of pacemakers of 1970 and one half that of present day, conventional units. This fact suggests that a realistic average life of the pulse generator is 4 years or more.
Download full-text PDF |
Source |
---|
Ann Transl Med
December 2024
Department of Cardiovascular Medicine, University of Kansas Medical Center, Kansas City, KS, USA.
Background: Patients with end-stage kidney disease (ESKD) are at high risk for coronary artery disease. We investigate the trends and outcomes of percutaneous coronary intervention (PCI) for stable ischemic heart disease (SIHD) in patients with ESKD.
Methods: We utilized the United States Renal Data System [2010-2018] to include adult patients with ESKD on dialysis for at least 3 months who underwent PCI for SIHD.
JACC Adv
December 2024
Division of Pediatric Cardiology, Department of Pediatrics, Texas Children's Hospital and Baylor College of Medicine, Houston, Texas, USA.
Background: Early clinical outcomes data for adjunctive systemic sirolimus therapy (SST) for moderate to severe pediatric pulmonary vein stenosis (PVS) are promising but limited.
Objectives: The authors aimed to characterize a cohort of patients treated with SST to determine if SST was associated with a reduction in frequency of PVS interventions.
Methods: Medical records of 45 patients with PVS treated with SST for ≥1 month from 2015 to 2022 were retrospectively reviewed.
An intelligent controlled spatiotemporal mode-locked (STML) fiber laser based on a photonic lantern (PL) is proposed and experimentally demonstrated. A pair of in-house developed PLs is spliced into the cavity in a back-to-back structure. This PL-based structure functions as a mode multiplexer/demultiplexer to generate higher-order spatial modes.
View Article and Find Full Text PDFThis study reports the observation of complete orthogonally polarized Raman scattering (OPRS) in a 1.0-km high-birefringence fiber (HBF). An incident pump pulse at 1560 nm with an energy of 2.
View Article and Find Full Text PDFAtoms in Rydberg states are an important building block for emerging quantum technologies. While excitation to Rydberg orbitals is typically achieved in more than tens of nanoseconds, the physical limit is in fact much faster, at the ten picoseconds level. Here, we tackle such ultrafast Rydberg excitation of a rubidium atom by designing a dedicated pulsed laser system generating 480 nm pulses of 10 ps duration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!