Rationale And Objectives: To summarize the chemical synthesis, physicochemical characterization, pharmacokinetic behavior, and biological evaluation of P743, a new macromolecular iodinated contrast medium.

Methods: The synthesis and molecular modeling of the iodinated macromolecule P743 are described. The pharmacokinetic profile was established in rabbits and rats. Acute toxicity in mice, renal tolerance in normal rabbits, and renal tolerance in uninephrectomized, dehydrated rats undergoing selective intrarenal injection was evaluated. In vitro permeability effects on isolated mastocytes and on the coagulation pathways were carried out. Computed tomography vascular imaging was performed after intravenous injection of P743 (300 mg I/kg) in rabbits and compared with the nonspecific nonionic agent iobitridol.

Results: P743 is a monodisperse, macromolecular iodinated contrast medium. In both rabbits and rats, P743 showed a pharmacokinetic profile consistent with that of a rapid-clearance blood-pool agent. Its diffusion through the endothelium was found to be low in vitro, thus confirming early confinement of this macromolecule, unlike nonspecific contrast media. In both species, P743 was excreted by glomerular filtration. Acute toxicity disclosed no mortality at the highest volume that could be injected into mice, leading to a median lethal dose greater than 8.9 g I/kg. Renal tolerance was found to be good in both euvolemic rabbits and uninephrectomized, dehydrated rats. No histamine or leukotriene B4 release was found on RBL-2H3 isolated mastocytes. P743 did not interfere with the coagulation pathways. Imaging experiments confirmed that P743 remains in the vascular compartment for a longer time than does iobitridol, thus allowing vascular enhancement that is twice as high as that of iobitridol in the recirculation phase.

Conclusions: The pharmacokinetic and imaging profiles of P743, a new, monodisperse, macromolecular blood-pool iodinated contrast medium, were consistent with those of a rapid-clearance blood-pool agent. Its initial safety profile is satisfactory. Further experimental imaging studies are required to define the clinical interest in such molecules.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00004424-200101000-00006DOI Listing

Publication Analysis

Top Keywords

iodinated contrast
12
renal tolerance
12
p743
10
macromolecular iodinated
8
pharmacokinetic profile
8
rabbits rats
8
acute toxicity
8
uninephrectomized dehydrated
8
dehydrated rats
8
isolated mastocytes
8

Similar Publications

Purpose: The objective of this study was to explore the feasibility of using the TianJi Robot system for navigated needle positioning in the PCNL procedure in vitro.

Methods: A pig kidney with a segment of ureter was selected as the in vitro organ model. Iodine contrast agent was infused into the renal pelvis to dilate the renal pelvis and calyx to establish the in vitro hydronephrosis model.

View Article and Find Full Text PDF

Objective: To compare iodine density (ID) and contrast-enhanced attenuation value (CEAV) from dual-layer spectral computed tomography (DLSCT) scans of lymphomatous, metastatic squamous cell carcinoma (SCCA), and normal cervical lymph nodes.

Methods: Data including ID and CEAV were retrospectively collected from patients who underwent DLSCT of the neck between January 2020 and August 2023. Results from each group (lymphomatous, metastatic SCCA, and normal) were compared and analyzed using one-way ANOVA and receiver operating characteristic curve.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Iodine concentration in the lung parenchyma in relation to different inspiratory depths during CT pulmonary angiography.

Br J Radiol

January 2025

Department of Radiology, Graduate School of Medicine, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo, 113-8655, Japan.

Objectives: This study aimed to investigate the impact of changing inspiratory depth from end- to mid-inspiratory level on the iodine concentration of lung parenchyma and main pulmonary artery in dual-energy CT pulmonary angiography.

Methods: This retrospective study included patients who underwent dual-energy CT pulmonary angiography from July 2020 to June 2023. Patients were instructed to hold their breath at end- and mid-inspiratory levels before and after January 2022, respectively.

View Article and Find Full Text PDF

Electrochromic materials were discovered in the 1960s when scientists observed reversible changes between the light and dark states in WO thin films under different voltages. Since then, researchers have identified various electrochromic material systems, including transition metal oxides, polymer materials, and small molecules. However, the electrochromic phenomenon has rarely been observed in non-metallic elemental substances.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!