BACKGROUND AND HYPOTHESIS: Dobutamine stress echocardiography is a well-established diagnostic method for investigating patients with suspected ischemic coronary disease. A positive test result is based on systolic parameters, but left ventricular filling parameters also are affected by myocardial ischemia. The aim of the present study was to study changes in both systolic and diastolic left ventricular variables throughout the test, including the period following it. METHODS AND RESULTS: Seven healthy control subjects (group I), 10 patients with chest pain but without significant coronary stenosis (group II), and 17 patients with significant coronary stenosis (group III) were entered in the study. Dobutamine stress echocardiography was performed according to a preset standardized protocol. Two-dimensional echocardiography and transmitral pulsed-Doppler images were stored for later analysis at rest, low dose, peak dose, and 5 minutes after termination of the dobutamine infusion. The wall motion score index increased from rest to low dose by 6.7% +/- 6.4% (P < 0.05) and to the peak dose by 39.1% +/- 9.9% (P < 0.001) in all three groups. The increase from rest to peak dose was significantly higher in groups I and II than in group III (P < 0.01). There was a significant increase in the atrial velocity-time integral (A-VTI) at peak dose in groups I and II (64.8% +/- 52.1% and 103.8% +/- 68.7%, respectively; P < 0.05 and <0.001), but no change in group III was noted. At the peak dose, A-VTI was significantly greater in groups I and II than in group III (P < 0.05). Among the 17 patients with proved coronary stenosis, 15 (88.2%) had a positive systolic response and 14 (82.3%) had a positive diastolic response, expressed as an A-VTI increase of

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8175.1998.tb00660.xDOI Listing

Publication Analysis

Top Keywords

peak dose
16
dobutamine stress
12
stress echocardiography
12
changes systolic
8
systolic diastolic
8
left ventricular
8
group patients
8
coronary stenosis
8
stenosis group
8
group iii
8

Similar Publications

As the second most populated country in Africa, Ethiopia needs public health measures to control diseases that impact its population. The goal of this study is to analyse disease burdens of HBV and HCV, while also highlighting their estimated associated costs for the country. A literature review and a Delphi process reflecting input of Ethiopian experts and the National Viral Hepatitis Technical Working Group were used to complement mathematical modelling to estimate HBV and HCV disease and economic burdens.

View Article and Find Full Text PDF

Lipid-encapsulated gold nanoparticles: an advanced strategy for attenuating the inflammatory response in SARS-CoV-2 infection.

J Nanobiotechnology

January 2025

Graduate School of Biotechnology, and College of Life Science, Kyung Hee University, Yongin-Si, 17104, Gyeonggi-Do, Republic of Korea.

Background: Nanodrugs play a crucial role in biomedical applications by enhancing drug delivery. To address safety and toxicity concerns associated with nanoparticles, lipid-nanocarrier-based drug delivery systems have emerged as a promising approach for developing next-generation smart nanomedicines. Ginseng has traditionally been used for various therapeutic purposes, including antiviral activity.

View Article and Find Full Text PDF

This study assesses radiation doses in multi-slice computed tomography (CT) using epoxy resin and PMMA phantoms, focusing on the relationship between TAR (tissue air ratio) and kilovoltage peak (kVp). The research was conducted using a Hitachi Supria 16-slice CT scanner. An epoxy resin phantom was fabricated from commercially available materials, to simulate human tissue.

View Article and Find Full Text PDF

Purpose: Due to the extensive use of radiation in various fields, such as food safety, sterilizing surgical materials, and medical diagnostics, it is essential to minimize radiation exposure for both patients and healthcare professionals, even at low doses. To meet this requirement, a composite film has been developed using polyvinyl alcohol (PVA) polymer and nitro blue tetrazolium (NBT) dye to measure low radiation doses effectively.

Methods: Various concentrations of NBT dye (ranging from 0.

View Article and Find Full Text PDF

DECT sparse reconstruction based on hybrid spectrum data generative diffusion model.

Comput Methods Programs Biomed

January 2025

Key Laboratory of Computer Network and Information Integration (Southeast University), Ministry of Education, Nanjing, China; School of Computer Science and Engineering, Southeast University, Nanjing, China.

Purpose: Dual-energy computed tomography (DECT) enables the differentiation of different materials. Additionally, DECT images consist of multiple scans of the same sample, revealing information similarity within the energy domain. To leverage this information similarity and address safety concerns related to excessive radiation exposure in DECT imaging, sparse view DECT imaging is proposed as a solution.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!