Objective: The objective was to review the current results of endovascular abdominal aortic aneurysm repair with the AneuRx stent graft and to determine the effectiveness of the device in achieving the primary objective of preventing aneurysm rupture.

Methods: The outcome of all patients treated during the past 4 years in the U.S. AneuRx clinical trial was determined, and the worldwide clinical experience was reviewed.

Results: A total of 1192 patients were treated with the AneuRx stent graft during all phases of the U.S. Clinical Trial from June 1996 to November 1999, with follow-up extending to June 2000. Ten (0.8%) patients have had aneurysm rupture, with most ruptures (n = 6) occurring in 174 (3.4%) patients treated with an early stiff bifurcation stent graft design used in phase I and in the initial stages of phase II. Since the current, flexible, segmented bifurcation stent graft design was introduced, four (0.4%) ruptures have occurred among 1018 patients treated. Of these, one was during implantation, two were placed too far below the renal arteries, and one patient refused treatment of a type I endoleak. Kaplan-Meier analysis of all 1192 patients treated with the AneuRx stent graft including both stent graft designs revealed the patient survival rate to be 93% at 1 year, 88% at 2 years, and 86% at 3 years, freedom from conversion to open repair to be 98% at 1 year, 97% at 2 years, and 93% at 3 years, and freedom from secondary procedure to be 94% at 1 year, 92% at 2 years, and 88% at 3 years. Freedom from aneurysm rupture with the commercially available segmented bifurcation stent graft was 99.7% at 1 year, 99.5% at 2 years, and 99.5% at 3 years. The presence or absence of endoleak on contrast computed tomography scanning after stent graft placement was not found to be a significant predictor of long-term outcome measures. Worldwide experience with the AneuRx device now approaches 10,000 patients.

Conclusions: Endovascular management of abdominal aortic aneurysms with the AneuRx stent graft has markedly reduced the risk of aneurysm rupture while eliminating the need for open aneurysm surgery in 98% of patients at 1 year and 93% of patients at 3 years. The device was effective in preventing aneurysm rupture in 99.5% of patients over a 3-year period. The overall patient survival rate was 93% at 1 year and 86% at 3 years.

Download full-text PDF

Source
http://dx.doi.org/10.1067/mva.2001.111676DOI Listing

Publication Analysis

Top Keywords

stent graft
40
aneurx stent
20
patients treated
20
aneurysm rupture
16
bifurcation stent
12
years freedom
12
years
11
graft
10
stent
9
patients
9

Similar Publications

Long-term data are limited comparing percutaneous coronary intervention (PCI) with second-generation drug-eluting stents (S-DES) vs coronary artery bypass grafting (CABG) in patients with complex coronary artery disease (CAD). We aimed to conduct a systematic review and meta-analysis comparing these interventions in patients with left main or multivessel CAD. We systematically reviewed PubMed, Embase, and Cochrane for studies that compared PCI with S-DES and CABG in patients with left main or multivessel CAD with a minimum mean follow-up period of 3 years.

View Article and Find Full Text PDF

A 14-year-old boy developed hydronephrosis and worsening renal function due to fibroepithelial polyps of the bladder and left ureter at the age of 12 years. The endoscopic treatment of ureteral polyps was attempted by his previous doctor; however urethral stricture and ureteral stricture developed and was untreatable. Therefore, he was referred to our hospital for further reconstructive treatment.

View Article and Find Full Text PDF

Introduction: Coarctation of the aorta is a congenital narrowing of the thoracic aorta associated with hypertension and significant pressure gradients across the coarctation site. Coarctoplasty by percutaneous approach is the preferred method of treatment. However, complications like stent dislodgement may result and must be immediately managed to prevent adverse outcomes.

View Article and Find Full Text PDF

Background & Aim: The definition and clinical relevance of percutaneous coronary intervention (PCI)-related myocardial infarction (MI) has been a topic of significant debate and controversy. It has particularly garnered widespread attention recently due to a contemporary trend of including it as a component of primary end points in major trials. The study aimed to assess the clinical relevance of PCI-related MI (PMI) according to the Fourth Universal Definition of MI using a high-sensitivity troponin (hs-Tn) assay in a real-world setting.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!