The aim of this study was to investigate the synergetic influence of surface topography and chemical composition of oral implant materials on bone response. For the experiment screw designed implants were used. The implants were grit-blasted with TiO2 particles. The implants were left uncoated (Ti) or provided with three different amorphous/crystalline Ca-P magnetron sputter coatings, resp. 0.1 micron (CaP-0.1), 1 micron (CaP-1) and 4 microns (CaP-4), in thickness. The implants were inserted in the medial femoral condyles of 12 goats. Each femur received 2 implants. After implantation periods of 6 and 12 weeks the implants were retrieved and prepared for histological and histomorphometrical evaluation (bone contact and bone mass). The light microscopy revealed that bone response to CaP-4 and CaP-1 implants was similar. For example, after 12 weeks, screw threads were almost completely covered with bone. In contrast to CaP-0.1 and Ti implants, where bone apposition was less pronounced. Histomorphometry demonstrated that the bone-to-implant contact for the CaP-1 and CaP-4 implants was significantly higher (P < 0.05) than for the CaP-0.1 and Ti implants. This difference existed already after 6 weeks and was even enhanced after 12 weeks. The bone mass measurements revealed that only at 12 weeks CaP-4 implants had significantly more bone contact inside the screw threads than non-coated Ti-implants (P < 0.05). Supported by our findings, we conclude that the additional application of a 1-4 microns thick Ca-P magnetron sputter coating can further improve the healing response to surface roughened oral implants placed into trabecular bone.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1034/j.1600-0501.2000.011004314.x | DOI Listing |
Oper Neurosurg (Hagerstown)
November 2024
Department of Neurologic Surgery, Mayo Clinic, Rochester, Minnesota, USA.
Background And Objectives: A typical workflow for deep brain stimulation (DBS) surgery consists of head frame placement, followed by stereotactic computed tomography (CT) or MRI before surgical implantation of the hardware. At some institutions, this workflow is prolonged when the imaging scanner is located far away from the operating room, thereby increasing workflow times by the addition of transport times. Recently, the intraoperative O-arm has been shown to provide accurate image fusion with preoperative CT or MR imaging, suggesting the possibility of obtaining an intraoperative localization scan and postoperative confirmation.
View Article and Find Full Text PDFASAIO J
January 2025
From the Division of Cardiac Surgery, Department of Surgery, Johns Hopkins University School of Medicine, Baltimore, Maryland.
The use of cardiac devices, including mechanical circulatory support (MCS), cardiac implantable electronic devices (CIEDs), and pacing wires, has increased and significantly improved survival in patients with severe cardiac failure. However, these devices are frequently associated with acute brain injuries (ABIs) including ischemic strokes, intracranial hemorrhages, seizures, and hypoxic-ischemic brain injury which contribute substantially to morbidity and mortality. Computed tomography (CT) and magnetic resonance imaging (MRI), the standard imaging modalities for ABI diagnosis, can pose significant challenges in this patient population due to the risks associated with patient transportation and the incompatibility of ferromagnetic components of certain cardiac devices with high magnetic field of the MRI.
View Article and Find Full Text PDFACS Appl Mater Interfaces
January 2025
Center of Translational Oral Research (TOR), Department of Clinical Dentistry, University of Bergen, Bergen 5009, Norway.
Wood-based nanocellulose is emerging as a promising nanomaterial in the field of tissue engineering due to its unique properties and versatile applications. Previously, we used TEMPO-mediated oxidation (TO) and carboxymethylation (CM) as chemical pretreatments prior to mechanical fibrillation of wood-based cellulose nanofibrils (CNFs) to produce scaffolds with different surface chemistries. The aim of the current study was to evaluate the effects of these chemical pretreatments on serum protein adsorption on 2D and 3D configurations of TO-CNF and CM-CNF and then to investigate their effects on cell adhesion, spreading, inflammatory mediator production , and the development of foreign body reaction (FBR) .
View Article and Find Full Text PDFPLoS One
January 2025
Department of Radiology, Chung-Ang University Gwangmyeong Hospital, Seoul, Republic of Korea.
This study aimed to evaluate the feasibility of VX2 tumor in rabbit auricles as an experimental model for intra-arterial embolization. This study was approved by our Institutional Animal Care and Use Committee. VX2 tumors were implanted in both auricles of 12 New Zealand White Rabbits.
View Article and Find Full Text PDFInt J Cardiovasc Imaging
January 2025
Cardiology, Endeavor NorthShore Cardiovascular Institute, Evanston, IL, USA.
This study aims to evaluate the implementation of concomitant CAD assessment on pre-TAVI (transcatheter aortic valve implantation) planning CTA (CT angiography) aided by CT-FFR (CT-fractional flow reserve) [The CT2TAVI protocol] and investigates the incremental value of CT-FFR to coronary CT angiography (CCTA) alone in the evaluation of patients undergoing CT2TAVI. This is a prospective observational real-world cohort study at an academic health system on consecutive patients who underwent CTA for TAVI planning from 1/2021 to 6/2022. This represented a transition period in our health system, from not formally reporting CAD on pre-TAVI planning CTA (Group A) to routinely reporting CAD on pre-TAVI CTA (Group B; CT2TAVI protocol).
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!