Purpose: To evaluate the use of deep inspiration breath hold (DIBH) during tangential breast radiation therapy as a means of reducing irradiated cardiac volume.
Methods And Materials: The Active Breathing Control (ABC) device designed at William Beaumont Hospital, Michigan was used to quantify the potential benefit of radiation delivery during DIBH for five left-sided breast cancer patients. This device initiates a breath hold at a predefined, reproducible lung volume. For each patient, two CT scans were acquired with and without breath hold, and virtual simulation was performed for regular tangent and wide-tangent techniques. The resulting dose-volume histograms were calculated, and the volume of heart irradiated to 25 Gy or more was assessed.
Results: The influence of ABC on irradiated heart volumes varied considerably among the five patients. Three patients with substantial cardiac volume in the treatment field during normal respiration showed a significant dose-volume histogram reduction when deep inspiration was applied, with decreases in the heart volume receiving 25 Gy of more than 40 cc observed. For one patient, deep inspiration reduced irradiated cardiac volumes only with the wide-tangent technique, while one patient showed no substantial irradiated volume decrease.
Conclusion: A DIBH technique during tangential breast irradiation has the potential to significantly decrease irradiated cardiac volume for suitably selected patients. The magnitude of the impact of the breath hold application depends on patient anatomy, lung capacity, and pulmonary function.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0360-3016(00)01455-3 | DOI Listing |
J Comput Assist Tomogr
November 2024
From the Department of Diagnostic Radiology, Graduate School of Medical Sciences, Kumamoto University, Kumamoto, Japan.
Objective: This preliminary study aims to assess the image quality of enhanced-resolution deep learning reconstruction (ER-DLR) in magnetic resonance cholangiopancreatography (MRCP) and compare it with non-ER-DLR MRCP images.
Methods: Our retrospective study incorporated 34 patients diagnosed with biliary and pancreatic disorders. We obtained MRCP images using a single breath-hold MRCP on a 3T MRI system.
Invest Radiol
January 2025
From the Department of Medical Imaging, Radboud University Medical Center, Nijmegen, the Netherlands (I.T.M., M.C.M., S.Y., R.v.d.E., A.V., E.J.S., J.J.H., T.W.J.S.); and Department of Radiology, NYU Langone Health, New York, NY (T.K.B.).
Objectives: Accurate lymph node (LN) staging is crucial for managing upper abdominal cancers. Ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance imaging effectively distinguishes healthy and metastatic LNs through fat/water and -weighted imaging. However, respiratory motion artifacts complicate detection of abdominal LNs.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Department of Radiology, Cincinnati Children's Hospital Medical Center, 3333 Burnet Avenue, Cincinnati, OH, 45229, USA.
Quantitative abdominal magnetic resonance imaging (MRI) offers non-invasive, objective assessment of diseases in the liver, pancreas, and other organs and is increasingly being used in the pediatric population. Certain quantitative MRI techniques, such as liver proton density fat fraction (PDFF), R2* mapping, and MR elastography, are already in wide clinical use. Other techniques, such as liver T1 mapping and pancreas quantitative imaging methods, are emerging and show promise for enhancing diagnostic sensitivity and treatment monitoring.
View Article and Find Full Text PDFEur J Radiol Open
June 2025
Department of Radiology, Charité - Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Berlin, Germany.
Background: Deep learning (DL) accelerated controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE), provides high spatial resolution T1-weighted imaging of the upper abdomen. We aimed to investigate whether DL-CAIPIRINHA-VIBE can improve image quality, vessel conspicuity, and lesion detectability compared to a standard CAIPIRINHA-VIBE in renal imaging at 3 Tesla.
Methods: In this prospective study, 50 patients with 23 solid and 45 cystic renal lesions underwent MRI with clinical MR sequences, including standard CAIPIRINHA-VIBE and DL-CAIPIRINHA-VIBE sequences in the nephrographic phase at 3 Tesla.
Radiat Oncol J
December 2024
Department of Radiation Oncology, Yonsei Cancer Center, Heavy Ion Therapy Research Institute, Yonsei University College of Medicine, Seoul, Republic of Korea.
Purpose: Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!