Purpose: Development of an optimized Spiral CT protocol type for the diagnosis of aortic dissections.
Material And Methods: 121 consecutive CT examinations applying 5 different protocol types were blindly read by two experienced radiologists and then compared with: (a) 45 biplane transesophageal echocardiographies (TEE), (b) 52 transthoracic echocardiographies (TTE), (c) 52 operative findings and, furthermore, related to the clinical course over at least six months in 79 patients.
Results: The sensitivity of the spiral computed tomography for detection of dissection was 97% (biplane TEE: 88%), the specificity 100% (biplane TEE: 91%). In 15% dissections with atypical origin and entries (mid-portion of the aortic arch, distal thoracic aorta, etc.) were found. The optimal CT-protocol was the one with a combination of two separate but adjacent spiral scans achieving high spatial resolution for the aortic arch and enough spatial resection for the residual aorta (1. helical scan 3 mm collimation, pitch 2. 2. helical scan 5 mm collimation and pitch 2, 130 ml contrast medium at 5 ml/s) with a classification accuracy of 100%, visualization of entries of 100%, reentries of 100% (40% direct, 60% indirect). The identification of the ostia of the aortic branches were: supraaortic 93%, visceral 100%, left renal artery 100%, right renal artery 93%, iliac 64%. The CT angiography, designed as aortic arch angiography, showed a good contrast in the aortic arch vessels (79-86%) and the visceral vessels too (91%).
Conclusion: Thoracic CT angiography can be used as gold standard in the primary evaluation of aortic dissections.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/s-2000-8372 | DOI Listing |
J Endovasc Ther
January 2025
Aortic Center, Hôpital Marie-Lannelongue, Groupe Hospitalier Paris Saint Joseph, Université Paris-Saclay, INSERM UMR_S 999, Le Plessis Robinson, France.
Introduction: Management of patients with large aortic arch aneurysms who are considered high risk for frozen elephant trunk technique have been challenging, especially when they have a dilated ascending aorta (AA) that precludes total endovascular branched repair (arch BEVAR). A viable option in our armamentarium is wrapping of the AA (AW), and zone 0 Ishimaru TEVAR.
Methods: Retrospective analysis of our aortic database from 2013 to 2024 to select high-risk patients with aortic arch aneurysm that had an AW and TEVAR.
J Vasc Surg Cases Innov Tech
April 2025
Division of Vascular Surgery and Endovascular Therapy, Department of Surgery, Case Western Reserve University School of Medicine, University Hospitals Harrington Heart and Vascular Institute, Cleveland, OH.
Transaortic endarterectomy (TE) is an effective and durable method of restoring patency in the aorta afflicted with atherosclerotic disease, which most commonly affects the infrarenal aorta and common iliac artery. When the suprarenal aorta is involved, the disease is usually confined to the orifices of the visceral vessels without obstruction of the aortic lumen. In rare cases, dense, calcified, exophytic, and amorphous lesions causing severe luminal obstruction, termed coral reef atherosclerosis (CRA) of the suprarenal aorta, may occur.
View Article and Find Full Text PDFMost thoracic aortic aneurysms (TAAs) are asymptomatic and often diagnosed at the time of rupture. TAAs involving the proximal arch require adequate coverage with thoracic endovascular aortic repair, which is timely and challenging in emergent ruptures. In situ laser fenestration is a novel method of arch revascularization.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Colorectal and Stomach Cancer Surgery-1, Jilin Cancer Hospital, Changchun, Jilin Province, China.
A 55-year-old woman with non-small cell lung carcinoma complained of epigastric pain, bloating, anorexia and postprandial nausea and vomiting over a five-year period. An upper gastrointestinal pan-glucosamine contrast examination revealed a distinctive large, hook-shaped, ptotic gastric lumen with normal motility. The contrast agent demonstrated an abnormal round-trip flow anterior to the spine at the duodenal level, with pooling and gradual passage through this region in strands after prolonged retention.
View Article and Find Full Text PDFEur Heart J Imaging Methods Pract
January 2025
Department of Radiology, University of Michigan, 1500 E Medical Center Drive, CVC 5581, Ann Arbor, MI 48109, USA.
Aims: Aortic wall stiffening in ascending thoracic aortic aneurysm (aTAA) is common. However, the spatial and temporal relationships between stiffness, aortic size, and growth in aTAA remain unclear.
Methods And Results: In this single-centre retrospective study, we utilized vascular deformation mapping to extract multi-directional aortic motion, aortic distensibility, and aortic growth in a multi-planar fashion from multi-phasic ECG-gated computed tomography angiograms.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!