A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High-frequency oscillations of the heart rate during ramp load reflect the human anaerobic threshold. | LitMetric

High-frequency oscillations of the heart rate during ramp load reflect the human anaerobic threshold.

Eur J Appl Physiol

Johannes-Müller Institute for Physiology, Humboldt University of Berlin, University Hospital Charité, Germany.

Published: November 2000

The aim of this study was to analyze the dynamic behavior of the high-frequency component (HF > 0.15 Hz) of heart rate variability (HRV) and the respiratory frequency in relation to the anaerobic threshold (AT). Twenty-two healthy subjects [mean (SD) age: 24 (6) years, height: 175 (10) cm, body mass: 65 (11) kg] completed a ramp load, with increments of 20 W x min(-1), on a cycle ergometer. The AT was determined by the V-slope-method. Respiratory movements of the thorax, and the electrocardiogram were monitored. The instantaneous frequency of the HF component of HRV and of the respiratory signal were obtained by the Hilbert transformation. Both frequencies were closely related, the cross correlation coefficient being between 0.84 and 0.99. Various patterns of HRV and respiration were observed during the protocol. Remarkably, however, in over 90% of these cases, a shift in the instantaneous frequency of the HF component occurred during the transition from aerobic to anaerobic work. The difference between the AT determined by gas analysis and the AT evaluated as the power output (ATf), calculated using the approximation of the curve of the instantaneous frequency of HF by hyperbolic tangent functions, varied between 2 and 14%. In conclusion, the present study demonstrates significant changes in the behavior of the instantaneous frequency of HF in the region of the AT.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s004210000302DOI Listing

Publication Analysis

Top Keywords

instantaneous frequency
16
heart rate
8
ramp load
8
anaerobic threshold
8
hrv respiratory
8
frequency component
8
frequency
5
high-frequency oscillations
4
oscillations heart
4
rate ramp
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!