A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Numerical simulation of the influence of a left ventricular assist device on the cardiovascular system. | LitMetric

Numerical simulation of the influence of a left ventricular assist device on the cardiovascular system.

Int J Artif Organs

Department of Biomedical Engineering, Faculty of Medical Sciences, University of Groningen, The Netherlands.

Published: November 2000

The PUCA (pulsatile catheter) pump is a left ventricular assist device (LVAD) capable of unloading the left ventricle (LV) and improving coronary flow by providing a counterpulsation effect. It consists of an extracorporeal located membrane pump, coupled to a transarterial catheter that enters the body via a superficial artery and ends in the LV. Blood is aspirated from the LV and pumped in the ascending aorta through the same catheter guided by a valve system. Timing and frequency of the PUCA pump influence its efficacy. To study the influence of several pump parameters a numerical model of the device and the circulatory system has been developed. Results of animal experiments were used to validate the model. Optimization studies resulted in a pump configuration with a stroke volume of 50 cc and pump:heart frequency mode of 1:2 that starts ejection at the beginning of diastole.

Download full-text PDF

Source

Publication Analysis

Top Keywords

left ventricular
8
ventricular assist
8
assist device
8
pump
5
numerical simulation
4
simulation influence
4
influence left
4
device cardiovascular
4
cardiovascular system
4
system puca
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!