A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Effects of beta(-)-emitting (188)Re balloon in stented porcine coronary arteries: an angiographic, intravascular ultrasound, and histomorphometric study. | LitMetric

Background: Restenosis within stents may be prevented by ionizing radiation from an intravascular source.

Methods And Results: A liquid beta(-) radiation ((188)Re) balloon was evaluated in a randomized and blinded porcine coronary model of stent restenosis. Group A pigs (n=17) received 0,16, 22, or 29 Gy at 0.5-mm depth, followed by stenting. Restenosis was quantified by angiography, ultrasound, and histomorphometry at 30 days. Group B (n=7) was stented first and then treated with 0 or 29 Gy with follow-up at 60 days. There was a measurable effect at 16 Gy, which improved with increasing doses. At 29 Gy, the histological stenotic area was reduced by 67% (22% versus 66% in controls, P<0.001). Radiation after stenting was equally effective; the stenotic area was reduced (21% versus 65%, P<0.001). At 16 Gy, the vessel just distal to the stent was significantly smaller than control vessels because of intimal thickening (P=0.003). Radiated vessels had distinctive histology consisting of neointimal fibrin and reduced smooth muscle cells and matrix (P<0.0001).

Conclusions: (188)Re balloon brachytherapy in porcine coronary arteries results in dose-dependent and injury-independent inhibition of stent restenosis for up to 60 days. Restenosis at the borders of the irradiated zone is a potential limitation and may be related to underdosing. Brachytherapy with the (188)Re balloon appears to be safe and feasible for clinical studies.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.cir.102.25.3117DOI Listing

Publication Analysis

Top Keywords

188re balloon
8
porcine coronary
8
effects beta--emitting
4
beta--emitting 188re
4
balloon stented
4
stented porcine
4
coronary arteries
4
arteries angiographic
4
angiographic intravascular
4
intravascular ultrasound
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!