Multisection computed tomography (CT) was introduced in 1992 with the advent of dual-section-capable scanners and was improved in 1998 following the development of quad-section technology. With a recent increase in gantry speed from one to two revolutions per second, multisection CT scanners are now up to eight times faster than conventional single-section helical CT scanners. The benefits of quad-section CT relative to single-section helical CT are considerable. They include improved temporal resolution, improved spatial resolution in the z axis, increased concentration of intravascular contrast material, decreased image noise, efficient x-ray tube use, and longer anatomic coverage. These factors substantially increase the diagnostic accuracy of the examination. The multisection CT technique has enabled faster and superior evaluation of patients across a wide spectrum of clinical indications. These include isotropic viewing, musculoskeletal applications, use of multiplanar reformation in special situations, CT myelography, long coverage and multiphase studies, CT angiography, cardiac scoring, evaluation of brain perfusion, imaging of large patients, evaluation of acute chest pain or dyspnea, virtual endoscopy, and thin-section scanning with retrospective image fusing. Multisection CT is superior to single-section helical CT for nearly all clinical applications.

Download full-text PDF

Source
http://dx.doi.org/10.1148/radiographics.20.6.g00nv071787DOI Listing

Publication Analysis

Top Keywords

single-section helical
12
clinical applications
8
multisection
5
multisection scanning
4
scanning techniques
4
techniques clinical
4
applications multisection
4
multisection computed
4
computed tomography
4
tomography introduced
4

Similar Publications

Purpose: In X-ray computed tomography (CT), X-rays are significantly less attenuated in the anteroposterior direction and more in the lateral direction. Therefore, the tube current should be adjusted within one gantry rotation using angular tube current modulation (TCM). The aim of this study was to evaluate whether online angular TCM could reduce radiation dose appropriately.

View Article and Find Full Text PDF

Radiation dose from single-heartbeat coronary CT angiography performed with a 320-detector row volume scanner.

Radiology

March 2010

Department of Medicine, Cardiology Division, Department of Radiology, and Center for Radiological Research, Columbia University Medical Center and New York-Presbyterian Hospital, 622 W 168th St, PH 10-203A, New York, NY 10032, USA.

Purpose: To determine radiation doses from coronary computed tomographic (CT) angiography performed by using a 320-detector row volume scanner and evaluate how the effective dose depends on scan mode and the calculation method used.

Materials And Methods: Radiation doses from coronary CT angiography performed by using a volume scanner were determined by using metal-oxide-semiconductor field-effect transistor detectors positioned in an anthropomorphic phantom physically and radiographically simulating a male or female human. Organ and effective doses were determined for six scan modes, including both 64-row helical and 280-row volume scans.

View Article and Find Full Text PDF

Regional survey of CT dose indices in India.

Radiat Prot Dosimetry

September 2009

Department of Radiology, Christian Medical College, Vellore, Tamil Nadu.

This study intends to evaluate the current level of computed tomography (CT) scanner doses installed in a region in India. In-site CT dose measurement was performed for 127 CT scanners in a region in India. CT dose index (CTDI) was measured using a 10 cm3 pencil ion chamber and 32-cm polymethyl methacrylate body phantom.

View Article and Find Full Text PDF

Purpose: To perform a systematic review to compare FDG-PET, CT, and MRI imaging for diagnosis of local residual or recurrent nasopharyngeal carcinoma.

Materials And Methods: MEDLINE, EMBASE, the CBMdisc databases and some other databases were searched for relevant original articles published from January 1990 to June 2007. Inclusion criteria were as follows: Articles were reported in English or Chinese; FDG-PET, CT, or MRI was used to detect local residual or recurrent nasopharyngeal carcinoma; histopathologic analysis and/or close clinical and imaging follow-up for at least 6 months were the reference standard.

View Article and Find Full Text PDF

Purpose: To measure radiation doses for computed tomography (CT) of the head, chest, and abdomen and compare them with the diagnostic reference levels, as part of the International Atomic Energy Agency Research coordination project.

Materials And Methods: The local ethics committees of all participating institutions approved the study protocol. Written informed consent was obtained from all patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!