A consecutive series of revision total knee arthroplasties performed at 3 university-affiliated centers by 3 surgeons was prospectively studied. The same implant was used in all cases. The evaluation included a Knee Society clinical score (KSCS); SF-36; satisfaction survey; and radiographs preoperatively, at 6 and 12 months postoperatively, and annually thereafter. Follow-up averaging 36 months (range, 24-60 months) was obtained in 125 of 138 knees (91%). Twenty-eight knees were infected, and 26 of 28 knees were treated successfully with 2-stage exchange with an interval of 4 to 6 weeks using an antibiotic-impregnated spacer block and intravenous antibiotics. The remaining 99 knees were revised for reasons other than infection, including aseptic component loosening, progressive osteolysis, and component instability. Preoperatively, patients with infection had a significantly decreased arc of motion compared with patients without infection (79 degrees vs 92 degrees; P<.05). There was a strong trend for the infected knees to have a lower preoperative KSCS than the noninfected knees, although this trend did not achieve statistical significance (76 vs. 92; P =.11). Postoperatively, patients with infection continued to have a significantly decreased range of motion (89 degrees vs. 99 degrees; P =.05). The postoperative KSCS was markedly lower in the septic versus aseptic revisions (115 vs. 135; P =.02). Patients with infection had a significantly lower function score (44 vs. 57; P =.03). A significantly higher percentage of patients stated that they were unable to return to normal activities of daily living after septic versus aseptic revision total knee arthroplasty (24% vs. 7%; P<.05). Despite the inferior functional result, patients expressed an equal degree of satisfaction with the results of their treatment in septic versus aseptic revision cases.

Download full-text PDF

Source
http://dx.doi.org/10.1054/arth.2000.16504DOI Listing

Publication Analysis

Top Keywords

revision total
8
total knee
8
patients infection
8
patient satisfaction
4
satisfaction outcome
4
outcome septic
4
septic versus
4
versus aseptic
4
aseptic revision
4
knee arthroplasty
4

Similar Publications

Background: In this study, we estimated the risk of surgically treated postoperative periprosthetic femoral fractures (POPFFs) associated with femoral implants frequently used for total hip arthroplasty (THA).

Methods: In this cohort study of patients who underwent primary THA in England between January 1, 2004, and December 31, 2020, POPFFs were identified from prospectively collected revision records and national hospital records. POPFF incidence rates, adjusting for potential confounders, were estimated for common stems.

View Article and Find Full Text PDF

Unicoronal synostosis is a rare condition leading to anterior plagiocephaly with facial scoliosis and deformation of the anterior cranial fossa. Fronto-orbital advancement and remodelling (FOAR) is the standard of care for management, aiming to normalise the brow shape and position while ameliorating the risk of raised intracranial pressure (ICP) throughout childhood. Published long-term surgical outcome data for unicoronal synostosis is lacking.

View Article and Find Full Text PDF

Large-Scale Validation of the Feasibility of GPT-4 as a Proofreading Tool for Head CT Reports.

Radiology

January 2025

From the Departments of Biomedical Systems Informatics (S.K., Jaewoong Kim, C.H., D.Y.) and Neurology (Joonho Kim, J.Y.), Yonsei University College of Medicine, 50-1 Yonsei-ro, Seodaemun-gu, Seoul 03722, Republic of Korea; Department of Radiology, Central Draft Physical Examination Office of Military Manpower Administration, Daegu, Republic of Korea (D.K.); Department of Radiology, Research Institute of Radiological Science and Center for Clinical Imaging Data Science (H.J.S. Y.K., S.J.), and Center for Digital Health (H.J.S., D.Y.), Yongin Severance Hospital, Yonsei University College of Medicine, Yongin, Republic of Korea; Department of Radiology, Gangnam Severance Hospital, Yonsei University College of Medicine, Seoul, Republic of Korea (S.H.L.); Departments of Radiology (M.H.) and Neurology (S.J.L.), Ajou University Hospital, Ajou University School of Medicine, Suwon, Republic of Korea; and Institute for Innovation in Digital Healthcare, Severance Hospital, Seoul, Republic of Korea (D.Y.).

Background The increasing workload of radiologists can lead to burnout and errors in radiology reports. Large language models, such as OpenAI's GPT-4, hold promise as error revision tools for radiology. Purpose To test the feasibility of GPT-4 use by determining its error detection, reasoning, and revision performance on head CT reports with varying error types and to validate its clinical utility by comparison with human readers.

View Article and Find Full Text PDF

Objective: To analyze data from patient information forms (PIFs) submitted to the manufacturer of a new 3-piece inflatable penile prosthesis (IPP), the Rigicon Infla10® , to summarize interim outcomes of 250 implantations in a single center, which is the largest series in Türkiye.

Methods: A retrospective review of PIFs from 250 patients implanted with the IPP between January 2021 and December 2023 was performed to assess patient characteristics, surgical data, device durability, patient satisfaction, and rates of reoperation for any reason.

Results: The mean ± SD (range) follow-up was 21.

View Article and Find Full Text PDF

Background: The importance of the subscapularis for reverse total shoulder arthroplasty has been demonstrated, especially for internal rotation and stability. In a deltopectoral approach, a detachment of the subscapularis is performed (tenotomy, tuberosity peeling, or osteotomy), but the tendon is not always repairable at the end. When it is repaired, healing is obtained in only 40%-76% of the cases, with potential consequences for the outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!