AI Article Synopsis

Article Abstract

The echocardiogram of the anterior leaflet of the mitral valve (ECHO) was compared to hemodynamic and cineroentgenographic data to evaluate its accuracy in timing mitral valve (MV) opening and closure, and to validate it as an indicator of MV motion. The ECHO, high speed cineroentgenography at 250 frames/sec, and/or measurement of intracardiac pressures allowed accurate timing of the events of MV motion in dogs on right heart bypass. The intersection of left ventricular and left atrial pressures in early diastole preceded the onset of rapid anterior motion of ECHO (D' point) by 17 to 33 plus or minus 7.6 msec; r equals 0.98. The onset of left ventricular systole occurred before the termination of final rapid posterior motion of the ECHO in end diastole (Co point) by 25 plus or minus 10 msec; r equals 0.96. Radiopaque clips were attached to the free edges of both leaflets of the MV. Cineroentgenographically determined plots of clip distance from the ultrasound transducer were morphologically similar to the simultaneously recorded ECHO. A delay of 23 plus or minus 3 (0 to 40) msec was observed in the ECHO peaks of diastolic anterior excursion compared to clip motion. Contrast medium advances beyond the free edges of MV leaflets mixing with left ventricular blood 43 plus or minus 3 msec after initial separation. These cineroentgenographic studies elucidate nonuniformity of leaflet motion responsible for ECHO delays. Thus, ECHO D' and Co correlate well with hemodynamic indicators of MV opening and closure. However, ECHO motion, although qualitatively similar, is unpredictably delayed compared to cineroentgenography of clips on the MV free edge. Since the ECHO correlates well with hemodynamic indices of MV opening and closure, this noninvasive technique can be used as a reference in the timing of intracardiac events and in the determination of systolic and diastolic time intervals.

Download full-text PDF

Source
http://dx.doi.org/10.1161/01.cir.51.1.88DOI Listing

Publication Analysis

Top Keywords

minus msec
16
mitral valve
12
opening closure
12
motion echo
12
left ventricular
12
echo
10
echocardiogram anterior
8
anterior leaflet
8
leaflet mitral
8
hemodynamic cineroentgenographic
8

Similar Publications

Comparison of 2D and 4D Flow MRI in Neonates Without General Anesthesia.

J Magn Reson Imaging

January 2023

Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund.

Background: Neonates with critical congenital heart disease require early intervention. Four-dimensional (4D) flow may facilitate surgical planning and improve outcome, but accuracy and precision in neonates are unknown.

Purpose: To 1) validate two-dimensional (2D) and 4D flow MRI in a phantom and investigate the effect of spatial and temporal resolution; 2) investigate accuracy and precision of 4D flow and internal consistency of 2D and 4D flow in neonates; and 3) compare scan time of 4D flow to multiple 2D flows.

View Article and Find Full Text PDF

The aim of this study was to verify the autonomic modulation and blood pressure after adenosine-5'-triphosphate (ATP) supplementation associated to acute aerobic exercise in hypertensive women. Eleven hypertensive women (age, 61.8±5.

View Article and Find Full Text PDF

Background/aims: To confirm the feasibility of using newly developed endoscopic ultrasound (EUS) with Zone sonography™ technology (ZST; Fujifilm Corp.).

Methods: Seventy-five patients with pancreatic disorders were enrolled: 45 with intraductal papillary mucinous neoplasm; 15 with ductal carcinoma; five with neuroendocrine tumors; three with serous cystic neoplasms; and seven with simple cysts.

View Article and Find Full Text PDF

A visual analog of mismatch negativity when stimuli differ in duration.

Neurosci Behav Physiol

July 2010

Laboratory of Higher Nervous Activity, Research Institute of Biology and Biophysics, Tomsk State University, Tomsk, Russia.

Event-linked brain potentials were studied in ten essentially healthy volunteers (six men, four women) aged 18-24 years. Subjects were presented with rare deviant and frequent standard visual stimuli in the standard odd-ball paradigm in conditions of active attention to stimulation and in conditions of distracted attention. Differences between deviant stimuli (50, 100, and 150 msec) and standard (200 msec) stimuli ranged from 50 to 150 msec.

View Article and Find Full Text PDF

Carotid-Femoral Pulse Wave Velocity: Impact of Different Arterial Path Length Measurements.

Artery Res

March 2010

Cardiovascular Aging Research Laboratory, Department of Kinesiology and Health Education, University of Texas at Austin, Austin, Texas.

BACKGROUND: Carotid-femoral pulse wave velocity (PWV) is the most established index of arterial stiffness. Yet there is no consensus on the methodology in regard to the arterial path length measurements conducted on the body surface. Currently, it is not known to what extent the differences in the arterial path length measurements affect absolute PWV values.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!