Formation of low time-bandwidth product, single-sided exponential optical pulses in free-electron laser oscillators.

Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics

School of Science and Engineering, University of Abertay Dundee, Bell Street, Dundee DD1 1HG, United Kingdom.

Published: September 2000

AI Article Synopsis

  • The study focuses on the shape of picosecond optical pulses generated by free-electron laser (FEL) oscillators, specifically how varying cavity detuning affects their characteristics.
  • For significant cavity detuning, the leading edge of the optical pulse exhibits an exponential form, influenced by both the cavity's detuning and its quality factor.
  • These findings are crucial for designing new infrared FEL facilities, as they help balance the need for short pulse durations with narrow spectral bandwidth essential for various spectroscopy techniques.

Article Abstract

The detailed shape of picosecond optical pulses from a free-electron laser (FEL) oscillator has been studied for various cavity detunings. For large values of the cavity detuning the optical pulse develops an exponential leading edge, with a time constant proportional to the applied cavity detuning and the quality factor of the resonator. This behavior has been observed at two separate FELs that have completely different resonator layouts and electron beam characteristics, and using different methods of optical pulse length measurement. The optical pulses have a full width at half maximum time-bandwidth product Deltat(FWHM)Deltaf(FWHM) of 0.2-0.3. The results presented here can be used to predict the optical pulse length and corresponding minimum spectral width that can be generated in a FEL pumped by short electron bunches. This is important for the design of new infrared free-electron laser user facilities, which need to make a balanced choice between short pulses for high temporal resolution and narrow bandwidth for linear and nonlinear spectroscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1103/physreve.62.4216DOI Listing

Publication Analysis

Top Keywords

optical pulses
12
free-electron laser
12
optical pulse
12
time-bandwidth product
8
pulses free-electron
8
cavity detuning
8
pulse length
8
optical
6
formation low
4
low time-bandwidth
4

Similar Publications

Purpose: Current technologies to define the zone of acute peripheral nerve injury intraoperatively are limited by surgical experience, time, cumbersome electrodiagnostic equipment, and interpreter reliability. In this pilot study, we evaluated a real-time, label-free optical technique for intraoperative nerve injury imaging. We hypothesize that fluorescence lifetime imaging (FLIm) will detect a difference between the time-resolved fluorescence signatures for acute crush injuries versus uninjured segments of peripheral nerves in sheep.

View Article and Find Full Text PDF

We report a nonlinear terahertz (THz) detection device based on a metallic bull's-eye plasmonic antenna. The antenna, fabricated with femtosecond laser direct writing and deposited on a nonlinear gallium phosphide (GaP) crystal, focuses incoming THz waveforms within the sub-wavelength bull's eye region to locally enhance the THz field. Additionally, the plasmonic structure minimizes diffraction effects allowing a relatively long interaction length between the transmitted THz field and the co-propagating near-infrared gating pulse used in an electro-optic sampling configuration.

View Article and Find Full Text PDF

Supercontinuum generation in scintillator crystals.

Sci Rep

January 2025

Laser Research Center, Vilnius University, Saulėtekio Avenue 10, LT-10223, Vilnius, Lithuania.

We present a comparative experimental study of supercontinuum generation in undoped scintillator crystals: bismuth germanate (BGO), yttrium orthosilicate (YSO), lutetium oxyorthosilicate (LSO), lutetium yttrium oxyorthosilicate (LYSO) and gadolinium gallium garnet (GGG), pumped by 180 fs fundamental harmonic pulses of an amplified Yb:KGW laser. In addition to these materials, experiments in yttrium aluminium garnet (YAG), potassium gadolinium tungstate (KGW) and lithium tantalate (LT) were performed under identical experimental settings (focusing geometry and sample thickness), which served for straightforward comparison of supercontinuum generation performances. The threshold and optimal (that produces optimized red-shifted spectral extent) pump pulse energies for supercontinuum generation were evaluated from detailed measurements of spectral broadening dynamics.

View Article and Find Full Text PDF

Phased structures for lossless ion manipulation offer significant improvements over the scanning second gate method for coupling with ion trap mass analyzers. With an experimental run time of under 1 min for select conditions and an average run time of less than 4 min, this approach significantly reduces experimental time while enhancing the temporal duty cycle. The outlined SLIM system connects to an ion trap mass analyzer via a PCB stacked ring ion guide, which replaces the commercial ion optics and capillary inlet.

View Article and Find Full Text PDF

Introduction: Hypertension is among the most significant non-communicable public health issues worldwide. High blood pressure, or hypertension, has been associated with severe health consequences, including death, aneurysms, stroke, chronic renal disease, eye damage, heart attack, heart failure, peripheral artery disease, and vascular dementia. Consequently, this study aimed to investigate the predictors linked to survival time and the progression of blood pressure measurements in hypertensive patients.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!