Using x-ray reflectivity to determine the structure of surfactant monolayers.

Phys Rev E Stat Phys Plasmas Fluids Relat Interdiscip Topics

Department of Physics, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213 and Colloids, Polymers, and Surfaces Program, Carnegie Mellon University, Pittsburgh, Pennsylvania 15213, USA.

Published: August 2000

Interactions among the multiple degrees of freedom of surfactant molecules cause fascinating richness in the structure of their monolayers. Beyond this scientific motivation for studying surfactant monolayers, the technological use of monolayers for interfacial control and molecular assembly demands a clear understanding of monolayer structure. X-ray and neutron reflectivity have become prime techniques for determining this structure. We present x-ray reflectivity data for a representative surfactant monolayer system and outline an objective procedure for obtaining the maximum amount of structural information possible. Our approach combines tight control of instrumental parameters, dynamically optimized Monte Carlo and simulated annealing to probe the chi(2) hypersurface, and a set of statistical criteria for accepting and rejecting fits. We justify our procedure through tests using simulated data. Results indicate that an ensemble of fits must be performed for each set of reflectivity data in order to survey the chi(2) hypersurface adequately. A single good fit may yield structural parameters which are quite misleading, yet physically plausible. Thus, one must never be satisfied with performing just a single fit. In cases for which multiple, statistically equivalent fits are obtained, the apparent ambiguity is substantially mitigated by averaging the parameters over the ensemble of good fits. We also introduce a method of dealing with cases for which a good fit may be extremely difficult to find. Our analysis procedures can be generalized to other monolayer or multilayer systems and are also applicable to neutron reflectivity.

Download full-text PDF

Source
http://dx.doi.org/10.1103/physreve.62.2405DOI Listing

Publication Analysis

Top Keywords

x-ray reflectivity
8
surfactant monolayers
8
structure x-ray
8
neutron reflectivity
8
reflectivity data
8
chi2 hypersurface
8
good fit
8
reflectivity determine
4
structure
4
determine structure
4

Similar Publications

Background: Stereotactic radiosurgery (SRS) is widely used for managing brain metastases (BMs), but an adverse effect, radionecrosis, complicates post-SRS management. Differentiating radionecrosis from tumor recurrence non-invasively remains a major clinical challenge, as conventional imaging techniques often necessitate surgical biopsy for accurate diagnosis. Machine learning and deep learning models have shown potential in distinguishing radionecrosis from tumor recurrence.

View Article and Find Full Text PDF

The use of Highly Oriented Pyrolytic Graphite (HOPG) reflectors is often proposed in the design of X-ray Crystal Spectroscopy (XCS) diagnostic systems for the next-generation tokamak devices, including the ITER project. This study introduces an experimental study based on the X-Ray Diffractometry (XRD) method to evaluate the performance of HOPG reflectors. The experimental method provides both the angular responses and the reflectivities of the HOPG reflectors.

View Article and Find Full Text PDF

Accurate metacognitive judgments about an individual's performance in a mental task require the brain to have access to representations of the quality and difficulty of first-order cognitive processes. However, little is known about how accurate metacognitive judgments are implemented in the brain. Here, we combine brain stimulation with functional neuroimaging to determine the neural and psychological mechanisms underlying the frontopolar cortex's (FPC) role in metacognition.

View Article and Find Full Text PDF

Application of ultrasound elastography and splenic size in predicting post-hepatectomy liver failure: Unveiling new clinical perspectives.

World J Gastroenterol

January 2025

Department of Gastroenterology, Nanchong Central Hospital, The Second Clinical Medical College, North Sichuan Medical College, Nanchong 637000, Sichuan Province, China.

In this article, we discuss the study by Cheng , published in the , focusing on predictive methods for post-hepatectomy liver failure (PHLF). PHLF is a common and serious complication, and accurate prediction is critical for clinical management. The study examines the potential of ultrasound elastography and splenic size in predicting PHLF.

View Article and Find Full Text PDF

Prediction of posthepatectomy liver failure in patients with hepatocellular carcinoma through ultrasound elastography.

World J Gastroenterol

January 2025

Department of Radiology, Zhejiang Provincial People's Hospital (Affiliated People's Hospital, Hangzhou Medical College), Hangzhou 310014, Zhejiang Province, China.

In this article, we comment on the article by Cheng published in recently. Posthepatectomy liver failure (PHLF) remains a leading cause of hepatectomy-related mortality and can be evaluated according to liver reserve function. Liver stiffness (LS) measured by ultrasonic elastography and spleen area demonstrate a strong correlation with hepatic proliferation, fibrosis, and portal vein congestion, thus indirectly reflecting liver reserve function.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!