Failure to detect ventricular tachycardia and/or ventricular fibrillation by implantable cardioverter defibrillators (ICDs) is a rare but serious problem. We report a case of failure to detect an episode of induced ventricular tachycardia by a dual chamber ICD, due to abbreviation of ventricular detection window secondary to programmed pacing parameters and a rate-smoothing algorithm. In this patient, the intradevice interaction was corrected by programming rate-smoothing off. This report highlights the potentially lethal consequences of critical timing relationships among the pacing function, arrhythmia detection, and the characteristics of the arrhythmia when using a modern dual chamber ICD. Physicians responsible for patients with ICDs must be aware of such interactions.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1046/j.1540-8167.2000.01285.x | DOI Listing |
J Hazard Mater
January 2025
Department of Analytical Chemistry, College of Chemistry, Jilin University, Changchun 130012, China. Electronic address:
Phthalate esters, particularly di(2-ethylhexyl) phthalate (DEHP), are widely used plasticizers found in various consumer products, posing significant environmental and health risks due to their endocrine-disrupting effects. In this study, a novel enzyme-free intra-capacitive biofuel cell self-powered sensor (ICBFC-SPS) was developed. The ICBFC-SPS integrated a ternary heterostructure-based capacitive anode and a cathode with a sensing interface into a single-chamber electrolytic cell.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
Section of Electrophysiology, Division of Cardiology, Department of Internal Medicine, Rush University Medical Center, 1653 W. Congress, Chicago, IL 60612, USA.
Although significant strides have been made in cardiac pacing, the field is still evolving. While transvenous permanent pacing is highly effective in the management of bradyarrhythmias, it is not risk free and may result in significant morbidity and, rarely, mortality. Transvenous leads are often the weakest link in a pacing system.
View Article and Find Full Text PDFBeijing Da Xue Xue Bao Yi Xue Ban
February 2025
Department of Plastic Surgery, Peking University Third Hospital, Beijing 100191, China.
Objective: To explore the application value of dual chamber round tissue expander in immediate breast reconstruction.
Methods: Sixteen patients, who had been provided immediate tissue expander/implant two-stage breast reconstruction using dual chamber round tissue expander in our hospital from March 2022 to October 2023, were involved in this study, and the relevant information was analyzed retrospectively. The overall design of the expander is a round shape, consisting of two equally divided semi-circular chambers.
Medicine (Baltimore)
January 2025
Department of Medical Imaging, Jincheng People's Hospital, Shanxi, China.
Rationale: Thrombus is the most common occupying lesion in the cardiac chambers, it is often distinguished from cardiac neoplastic occupations. Among them, the most common is cardiac myxoma, whose imaging manifestations are often confused with thrombus. However, the 2 types of lesions have different therapeutic strategies and are both potentially high-risk sources of embolism, so early differentiation between intracardiac thrombus and cardiac tumor is essential.
View Article and Find Full Text PDFNanomaterials (Basel)
January 2025
Department of Physics and Astronomy, University of North Carolina at Chapel Hill, Chapel Hill, NC 27599-3255, USA.
In this study, a single zirconium carbide (ZrC) nanoneedle structure oriented in the <100> direction was fabricated by a dual-beam focused ion beam (FIB-SEM) system, and its field emission characteristics and emission current stability were evaluated. Benefiting from controlled fabrication with real-time observation, the ZrC nanoneedle has a smooth surface and a tip with a radius of curvature smaller than 20 nm and a length greater than 2 μm. Due to its low work function and well-controlled morphology, the ZrC nanoneedle emitter, positioned in a high-vacuum chamber, was able to generate a single and collimated electron beam with a current of 1.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!