Purpose: To determine the diameter and morphology of infrarenal aortic aneurysms in 78 fresh autopsy specimens.

Methods: To avoid underestimation of the arterial diameter postmortem and to re-establish aneurysm morphology, a device was designed and introduced into the vessel, inflated to 80 mm Hg, and the largest external diameter was measured.

Results: The ages of the individuals ranged from 40 to 97 yr (mean 70). Thirty-eight aneurysms were ruptured with diameters ranging from 5.3 to 17.0 cm (mean 7.97), and 40 aneurysms were nonruptured with variations in diameters from 2.8 to 6.1 cm, mean 4.02 cm (P<0.01). Fusiform aneurysms were more frequent, and when they ruptured their diameters were smaller than the diameters of the spherical aneurysms (P<0.05). Aneurysms ruptured more frequently in the posterior wall (67%) and in the inferior portion (61%). A mural thrombus was found at the site of rupture in 80% of the specimens.

Conclusion: In our samples, rupture was found solely in those aneurysms with a diameter over 5.0 cm, ruptures occurred earlier in fusiform aneurysms, mural thrombus was not a protective factor, and finally, aneurysms ruptured mainly in the posterior and inferior portions.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0967-2109(00)00060-0DOI Listing

Publication Analysis

Top Keywords

infrarenal aortic
8
aortic aneurysms
8
morphology diameter
4
diameter infrarenal
4
aneurysms
4
aneurysms prospective
4
prospective autopsy
4
autopsy study
4
study purpose
4
purpose determine
4

Similar Publications

Purpose: The goal of the study described in this protocol is to build a multimodal artificial intelligence (AI) model to predict abdominal aortic aneurysm (AAA) shrinkage 1 year after endovascular aneurysm repair (EVAR).

Methods: In this retrospective observational multicenter study, approximately 1000 patients will be enrolled from hospital records of 5 experienced vascular centers. Patients will be included if they underwent elective EVAR for infrarenal AAA with initial assisted technical success and had imaging available of the same modality preoperatively and at 1-year follow-up (CTA-CTA or US-US).

View Article and Find Full Text PDF

Thoracoabdominal aortic aneurysm (TAAA) repair remains one of the most challenging procedures and is associated with high mortality and complication rates. Careful consideration of the surgical strategy is essential, particularly in cases involving extensive replacement and high-risk patients. A 61-year-old man with a 55-mm TAAA was referred for surgical treatment.

View Article and Find Full Text PDF

Objective: Neutrophil-to-lymphocyte ratio (NLR) is a readily available parameter, associated with long-term outcomes in cardiovascular conditions. This study aims to analyze the predictors of NLR and its impact on prognosis and disease-specific outcomes following EVAR.

Methods: Single-center retrospective cohort study.

View Article and Find Full Text PDF

Objectives: To report the technical and clinical outcomes of endovascular repair of all infrarenal, penetrating aortic ulcers (PAU) that were treated at a single institution over a 13-year period.

Methods: This is a single-center, retrospective observational study. All patients consecutively treated for atherosclerotic, infrarenal PAU were included between 2010 and 2023.

View Article and Find Full Text PDF

Omniflow prosthesis for treatment prosthetic graft infection of the aorto-iliac and femoropopliteal level on the infrarenal aortic segment and lower extremity.

Ann Vasc Surg

January 2025

Department of for Cardiovascular Surgery, University Heart Centre Freiburg - Bad Krozingen, University Medical Centre Freiburg, Freiburg, Germany; Faculty of Medicine, Albert Ludwigs University Freiburg, Freiburg, Germany.

Objectives: To report outcomes after the use of the Omniflow II biosynthetic graft (LeMaitre Vascular, Il, USA) for vascular reconstruction in patients with prosthetic infection at the aorto-iliac and femoropopliteal level.

Methods: Within a six-year period, all consecutive patients with aorto-iliac and femoro-popliteal graft infection treated by resection of the infected graft material, extensive local debridement and reconstruction using Omniflow II biosynthetic graft were retrospectively analzyed. Patient characteristics, intraoperative details, postoperative outcomes, and infection details were assessed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!