Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To evaluate the feasibility and safety of endovascular stent-graft placement in treating Stanford type B aortic dissection.
Materials And Methods: Seven patients underwent endovascular stent-graft placement for type B aortic dissection. Five patients had acute and two had chronic dissection. In five patients, the proximal entry tear was within 2 cm of the origin of the left subclavian artery, and in two patients it was beyond this site. In three patients, the noncovered proximal portion of the stent-graft was placed across the origin of the left subclavian artery. The efficacy of the procedure was assessed at follow-up studies 3, 6, 12, and 24 months after intervention.
Results: The procedure was technically and clinically successful in six patients (86%). The left subclavian artery remained patent in all patients. In two patients with involvement of aortic branches, endovascular stent-graft placement restored adequate blood flow to the compromised branches. One patient was readmitted 1 month later because the dissection extended into the ascending aorta. In all but this patient, closure of the entry tear and thrombosis of the false lumen along the stent-graft were achieved. All false lumina shrank considerably. The mean follow-up time was 14 months (range, 1-25 months).
Conclusion: Type B aortic dissections within and beyond 2 cm of the origin of the left subclavian artery can be treated safely and effectively by means of endovascular stent-graft placement.