The dosimetric behaviour of a Scanditronix p-type silicon diode and a PTW natural diamond detector was studied in low-energy proton beams in the 8.3-21.5 MeV range. The properties investigated were linearity, reproducibility, dose rate dependence, energy and linear energy transfer (LET) dependence. The influence of detector thickness on the results of depth dose measurements was also demonstrated. A Markus parallel plate ionization chamber was used for reference dosimetry. Silicon diode and diamond detectors showed linearity at therapeutic dose level, reproducibility better than 1% (1sigma) and sensitivity variation with dose rate and proton energy.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/45/10/320DOI Listing

Publication Analysis

Top Keywords

diamond detectors
8
low-energy proton
8
proton beams
8
silicon diode
8
dose rate
8
dosimetric characterization
4
characterization silicon
4
silicon diamond
4
detectors low-energy
4
beams dosimetric
4

Similar Publications

The Particle Time of Flight (PTOF) diagnostic is a chemical vapor deposition diamond-based detector and is the only diagnostic for measuring nuclear bang times of low yield (<1013) shots on the National Ignition Facility. Recently, a comprehensive study of detector impulse responses revealed certain detectors with very fast and consistent impulse responses with a rise time of <50 ps, enabling low yield burn history measurements. At the current standoff of 50 cm, this measurement is possible with fast 14 MeV neutrons from deuterium-tritium (DT) fusion plasmas.

View Article and Find Full Text PDF
Article Synopsis
  • Proton Minibeam Radiation Therapy has been promising in enhancing treatment efficacy compared to traditional radiation, but more research into its biological mechanisms is needed.
  • A mechanical collimation setup was developed to produce 250µm minibeams with a 1000µm spacing, with optimization using Monte Carlo simulations conducted at various proton therapy sites.
  • Results showed a peak-to-valley dose ratio (PVDR) of 10 in Dresden and 14 in Seattle, with some discrepancies between dosimetry methods that can be addressed with correction factors.
View Article and Find Full Text PDF

For many synchrotron radiation experiments, it is critical to perform continuous, real-time monitoring of the X-ray flux for normalization and stabilization purposes. Traditional transmission-mode monitors included metal mesh foils and ionization chambers, which suffered from low signal stability and size constraints. Solid-state detectors are now considered superior alternatives for many applications, offering appealing features like compactness and signal stability.

View Article and Find Full Text PDF

Simultaneous detection of a wide range of synthetic and natural dyes in artworks using UHPLC-PDA-HRMS.

J Chromatogr A

January 2025

Analytical Sciences, van 't Hoff Institute for Molecular Sciences, Faculty of Sciences, University of Amsterdam, Science Park 904, 1098 XH Amsterdam, the Netherlands; Conservation and Restoration of Cultural Heritage, Amsterdam School for Heritage, Memory and Material Culture (AHM), Faculty of Humanities, University of Amsterdam, P.O. Box 94552, 1090 GN, Amsterdam, the Netherlands; Centre of Analytical Sciences Amsterdam, Science Park, 904, 1098 XH Amsterdam, The Netherlands. Electronic address:

This paper presents a validated method using ultra-high pressure liquid chromatography with photodiode array detection coupled to high-resolution mass spectrometry (UHPLC-PDA-HRMS) for the simultaneous analysis of a wide range of natural and synthetic organic colourants, including neutral, acidic and basic dyes. In total, 30 natural and 62 synthetic organic dye reference samples (which contain 118 compounds because some of the dyes are composed of mixtures) were analysed. The method demonstrated good linearity for the 12 dyes selected for method validation achieving correlation coefficients (R) exceeding 0.

View Article and Find Full Text PDF

In this project, we conducted micro-beam sensitivity mapping using the Diamond Light Source (DLS) synchrotron. We fabricated three samples with distinct metal contacts: Platinum (HPS-Pt) and Aluminium/Platinum (HPS-Al/Pt) on high-quality single crystal CVD diamond, and Platinum (VS-Pt) on lower purity single crystal CVD diamond. Our objective was to identify the most suitable sample for synchrotron measurements, particularly focusing on the lower purity sample due to its unique characteristics, such as thin nitrogen lines and substrate area.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!