The purpose of this study was to test the feasibility of real-time magnetic resonance (MR) guidance of iliac artery stent placement. Radial scanning together with the sliding window reconstruction technique was implemented on a 1.5 T magnet, yielding a frame rate of 20 images per second. Seven prototype nitinol ZA stents were deployed in iliac arteries of living pigs under MR control. All stents were well visualized on the radial MR images, allowing depiction of the mounted stents as well as stent deployment without anatomy-obscuring artifacts. Stent placement was sucessful in all cases and took 6 minutes on average. The position of the stents was correctly visualized by real-time radial MR scanning, as proved by digital subtraction X-ray angiography. Combined radial scanning and the sliding window reconstruction technique allow real-time MR-guided stent placement in iliac arteries.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/1522-2586(200010)12:4<616::aid-jmri15>3.0.co;2-f | DOI Listing |
J Glaucoma
January 2025
Department of Ophthalmology, Tan Tock Seng Hospital, National Healthcare Group Eye Institute, Singapore.
Purpose: Trabecular micro-bypass devices (TBDs) such as the iStent series (Glaukos Corporation, Laguna Hills, CA), are effective in reducing intraocular pressure (IOP). However, precise placement of TBDs is crucial in achieving surgical efficacy, as device malpositioning may lead to suboptimal IOP reduction. We demonstrate two novel intra-operative signs to aid confirmation of accurate iStent placement, without reliance on imaging technologies.
View Article and Find Full Text PDFTurk J Gastroenterol
January 2025
Department of Gastroenterology, Harran University Faculty of Medicine, Şanlıurfa, Türkiye.
Background/aims: Endoscopic retrograde cholangiopancreatography (ERCP) is an essential diagnostic and therapeutic method for pancreato-biliary disorders in adults, but its use in pediatric populations remains limited. This study aims to evaluate the indications, technical success, and safety of ERCP in pediatric patients.
Materials And Methods: A retrospective analysis of all ERCP procedures performed on patients under 18 years of age was conducted at 2 tertiary centers in Türkiye (Harran University and Gaziantep University Hospital) during the period between January 2013 and May 2024.
Case Rep Gastrointest Med
January 2025
Gastroenterology and Hepatology Unit, The Canberra Hospital, Australian Capital Territory, Canberra, Australia.
We present a case of an 80-year-old female who presented with chest pain, vomiting and night sweats a few weeks post thoracic endovascular aortic aneurysm repair (TEVAR). A computed tomography (CT) scan demonstrated a type 1B endoleak for which she underwent a repeat TEVAR. Postoperatively, she developed fever, dysphagia, haematemesis and melaena.
View Article and Find Full Text PDFJ Vasc Surg Cases Innov Tech
April 2025
Department of Surgery, Westchester Medical Center, Valhalla, NY.
We present a case of an 86-year-old female with chronic mesenteric ischemia secondary to long-segment flush occlusion of the superior mesenteric artery and near-total occlusion of the celiac artery. The superior mesenteric artery was unable to be revascularized by conventional antegrade approaches. Successful transcollateral crossing of the occluded superior mesenteric artery and body-flossing, followed by antegrade balloon angioplasty, shockwave lithotripsy, and stent implantation were performed.
View Article and Find Full Text PDFPediatr Transplant
February 2025
Division of Pediatric Cardiology, Department of Pediatrics and Adolescent Medicine, Mayo Clinic, Rochester, Minnesota, USA.
Background: In recent years, transcatheter implantation devices to restrict pulmonary arterial flow have emerged as a potential alternative to surgical pulmonary artery banding.
Case Presentation: A term male was diagnosed with critical aortic stenosis (AS) and severely reduced left ventricle (LV) systolic function. He underwent aortic balloon valvuloplasty on day 2 of life, resulting in some antegrade flow, but LV ejection fraction only improved to 15%.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!