Wear of alumina-on-alumina total hip arthroplasties at a mean 11-year followup.

Clin Orthop Relat Res

Laboratoire de Recherches Orthopédiques, UPRES-A CNRS 7052, Paris, France.

Published: October 2000

The surface topography of 11 alumina-on-alumina hip arthroplasties retrieved for aseptic loosening at a mean 11-year followup was investigated. Macroscopic wear was assessed using a coordinate measuring machine. Microscopic wear features were evaluated by Talysurf analysis. Scanning electron microscopy was used to look at the alumina microstructure. Components were classified into three groups: (1) low wear with no sign of wear and average arithmetic roughness values below 0.05 microm; (2) stripe wear with a visible oblong worn area on the femoral heads and penetration rates below 10 microm/year; and (3) severe wear with a visible loss of material on both components, showing total roughness values as much as 4 microm and maximum penetrations higher than 150 microm. Alumina quality assessed by grain size measurements and porosity percentages improved progressively from 1977 to 1988. This resulted in a correlated decrease of the microscopic wear magnitude. However, on a macroscopic scale, factors responsible for either a load increase (weight, young age, and male gender) or impairment in the load distribution over the component surfaces (large grain size, nonoptimal initial cup inclination, and cup migration and/or tilting) increased the penetration rates.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00003086-200010000-00014DOI Listing

Publication Analysis

Top Keywords

wear
8
hip arthroplasties
8
11-year followup
8
microscopic wear
8
roughness values
8
wear visible
8
penetration rates
8
grain size
8
wear alumina-on-alumina
4
alumina-on-alumina total
4

Similar Publications

Optical techniques, such as functional near-infrared spectroscopy (fNIRS), contain high potential for the development of non-invasive wearable systems for evaluating cerebral vascular condition in aging, due to their portability and ability to monitor real-time changes in cerebral hemodynamics. In this study, thirty-six healthy adults were measured by single channel fNIRS to explore differences between two age groups using machine learning (ML). The subjects, measured during functional magnetic resonance imaging (fMRI) at Oulu University Hospital, were divided into young (age ≤ 32) and elderly (age ≥ 57) groups.

View Article and Find Full Text PDF

Mechanical Wear of Degraded Articular Cartilage.

Ann Biomed Eng

January 2025

School of Mechanical Engineering, Purdue University, West Lafayette, IN, 47907, USA.

Purpose: To evaluate the mechanical wear of cartilage with different types of degradation.

Methods: Bovine osteochondral explants were treated with interleukin-1β (IL-1β) to mimic inflammatory conditions, with chondroitinase ABC (ChABC) to specifically remove glycosaminoglycans (GAGs), or with collagenase to degrade the collagen network during 5 days of culture. Viscoelastic properties of cartilage were characterized via indentation.

View Article and Find Full Text PDF

Measurement and Assessment of Head-to-Helmet Contact Forces.

Ann Biomed Eng

January 2025

Department of Mechanical and Industrial Engineering, Northeastern University, 360 Huntington Avenue, Boston, MA, 02115, USA.

Purpose: To evaluate the population variation in head-to-helmet contact forces in helmet users.

Methods: Four different size Kevlar composite helmets were instrumented with contact pressure sensors and chinstrap tension meters. A total number of 89 volunteers (25 female and 64 male volunteers) participated in the study.

View Article and Find Full Text PDF

The composition of the metal-polymer friction pair is carefully considered for interacting with water and hydrogen, ensuring the metals electrode process potential remains below waters in a neutral medium. Simultaneously, adherence to defined chemical composition ratios for the metal-polymer materials is crucial. This analysis is conducted under conditions of thermal stabilization, characterized by a minimal temperature gradient across the rim thickness within an equivalent thermal field.

View Article and Find Full Text PDF

Background Recommendations regarding long-term postoperative activity are intended to prevent adverse events, but no common policy or best practice exists among ophthalmologists for pediatric patients. We surveyed ophthalmologists on their postoperative guidelines after the one-month postoperative period following childhood cataract and glaucoma surgeries. Methods A 28-question anonymous Qualtrics survey was distributed via listservs and social media.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!