Background: Even though many types of reconstruction after total gastrectomy have been proposed to reduce postgastrectomy syndromes, choosing a method that would further improve the quality of life and nutrition of the gastrectomized patient is controversial. Hunt-Lawrence single pouch reconstruction seems to obtain better results compared with the more common Roux-en-Y technique, but both of these reconstructive approaches are associated with some reduction in food intake and some problems in achievement of ideal body weight.

Methods: In this prospective, randomized trial, after total gastrectomy 18 patients had reconstruction according to the Hunt-Lawrence or single pouch technique (SP group), whereas for 23 patients, the technique was modified with construction of a second pouch in the distal portion of the jejunal loop (DP group). Patients in the two groups were compared at 12 months after surgery for problems in gastrointestinal function, quality of life, improvement in body weight and nutritional parameters, serum albumin, hemoglobin level, and serum protein.

Results: The DP group demonstrated fewer symptom problems, better weight maintenance, and better laboratory values when compared with patients undergoing standard single jejunal pouch reconstruction.

Conclusions: Reconstruction with use of a double pouch as a gastric substitute leads to better outcome assessments than with a single pouch reconstruction. Our double pouch technique has demonstrated significant improvement in quality of life and nutritional recovery in terms of functional results as well as patient satisfaction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0002-9610(00)00419-0DOI Listing

Publication Analysis

Top Keywords

pouch reconstruction
12
total gastrectomy
12
quality life
12
single pouch
12
pouch
8
jejunal pouch
8
reconstruction total
8
hunt-lawrence single
8
pouch technique
8
group patients
8

Similar Publications

Background: Esophageal atresia is one of the most common life-threatening congenital malformations and is defined as an interruption in the continuity of the esophagus with or without fistula to the trachea or bronchi. Definitive treatment is surgical ligation of the fistula if present and esophageal end-to-end anastomosis of the two pouches, thereby reconstructing the continuity of the esophagus. During this procedure, the surgeon may choose to either ligate or preserve the azygos vein, a major draining vein for the esophagus and surrounding structures, but no definitive consensus on the matter exists.

View Article and Find Full Text PDF

Aqueous zinc-ion batteries promise low-cost and safe grid storage, but their practical application is hindered by poor Zn anode reversibility, primarily due to dendrite formation and water-induced side reactions in the electric double layer (EDL) structure. Herein, a monolayer of hydrophobic carbon dots (CDs) was dynamically constructed at the electrode/electrolyte interface. The trace-added hydrophobic CDs in the electrolyte reconstruct a hydrophobic and favorable EDL structure, suppressing water-induced side reactions in the inner Helmholtz layer and facilitating the desolvation of hydrated zinc ions at the outer Helmholtz layer.

View Article and Find Full Text PDF

Background: There is limited data within the urologic literature regarding bowel complications and leak rates following surgery requiring ileocolic anastomoses such as right colon pouch (RCP) and continent cutaneous ileocecocystoplasty (CCIC). We aimed to establish ileocolic anastomotic leak rates in urologic reconstructive surgery and determine bowel-related complications following RCP and CCIC surgeries.

Methods: We reviewed adult patients who underwent RCP or CCIC (2010-2022), investigating patient characteristics, perioperative variables, and outcomes.

View Article and Find Full Text PDF

Zn metal is the most attractive anode material for aqueous batteries, yet it encounters challenges from dendrites. Here, based on lanthanum trifluoromethanesulfonate (La(OTf))-based electrolyte, the idea of tailoring the electrode interface microenvironment (ion concentration, solid electrolyte interphase (SEI) and electric field) is proposed to stabilize the Zn metal anode. The theoretical and experimental results show that the reconstruction of the electrolyte microstructure by OTf and the capture of SO by La enhance the liquid-phase mass transfer, which alleviates the ion concentration gradient on the anode surface.

View Article and Find Full Text PDF

Objective: Blister aneurysms of the internal carotid artery (ICA) are rare and are primarily documented in the literature through small series and case reports. The intraoperative observation of a hemorrhage in the artery wall proximal to the aneurysmal bulge led to the hypothesis that some of these aneurysms might develop in a retrograde manner.

Methods: We developed software to reconstruct the ICA with and without Type I and II blister aneurysms using patients' imagery as input to simulate hemodynamic conditions before and after their formation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!