Matrix metalloproteinases (MMPs) have been reported to be the major factors responsible for aseptic loosening of artificial hip joints. So far, messenger ribonucleic acid (mRNA) expression patterns of seven MMPs have been reported, but that of many other MMPs which have been newly discovered or recently considered to be responsible for prosthetic loosening is still unknown. In this study, mRNA expression pattern of 16 different types of MMPs were analyzed to evaluate which MMPs were locally produced and contributed to prosthetic loosening. Synovium-like interface tissues between bone and prosthesis were collected from 18 cases of aseptic loose artificial hip joint at revision surgery. Six cases of normal synovium were used as controls. Total RNA was extracted by single-step acid guanidinium-thiocyanate-phenol-chloroform procedure. mRNA expression of MMPs was analyzed by semiquantitative reverse transcription-polymerase chain reaction. Based on local expression pattern of MMPs at the mRNA level, aseptic loose artificial hip joint was characterized by elevated expression of MMP-1, MMP-9, MMP-10, MMP-12, and MMP-13; moderate expression of MMP-2, MMP-7, MMP-8, MMP-11, membrane type (MT)1-MMP (MMP-14), MT2-MMP (MMP-15), MT3-MMP (MMP-16), MT4-MMP (MMP-17), and MMP-19; lower expression of MMP-3; and little significance of MMP-20. The MMPs detected in this study can potentially degrade almost all components of the periprosthetic extracellular matrix. Thus, many MMP type enzymes possibly contribute to prosthetic loosening and osteolysis through pathologic extracellular matrix degradation and connective tissue/bone remodeling around prostheses.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/1097-4636(20001215)52:4<613::aid-jbm5>3.0.co;2-8 | DOI Listing |
Br J Hosp Med (Lond)
January 2025
Department of Osteoarthritis, Yantai City Yantai Shan Hospital, Yantai, Shandong, China.
Deep venous thrombosis (DVT) represents a significant postoperative complication after artificial femoral head replacement, with the incidence increasing proportionally with patient age. This study aimed to evaluate the effect of early postoperative use of intermittent pneumatic compression devices (IPC), followed by the combined use of low molecular weight heparin (LMWH) after 48 hours, for the prevention of postoperative lower limb DVT in elderly patients undergoing hip arthroplasty. The retrospective study included 100 elderly patients who underwent unilateral femoral head replacement.
View Article and Find Full Text PDFMedicina (Kaunas)
January 2025
Department of Orthopedic Surgery, The Keck School of Medicine of USC, Los Angeles, CA 90033, USA.
: Measuring joint range of motion (ROM) is essential for diagnosing and treating musculoskeletal diseases. However, most clinical measurements are conducted using conventional devices, and their reliability may significantly depend on the tester. This study implemented an RGB-D (red/green/blue-depth) sensor-based artificial intelligence (AI) device to measure joint ROM and compared its reliability with that of a universal goniometer (UG).
View Article and Find Full Text PDFMetabolites
January 2025
Group for Hematology and Stem Cells, Institute for Medical Research, National Institute of Republic of Serbia, University of Belgrade, 11000 Belgrade, Serbia.
Background/objectives: Bone marrow adipose tissue (BMAT) has been described as an important biomechanic and lipotoxic factor with negative impacts on skeletal and hematopoietic system regeneration. BMAT undergoes metabolic and cellular adaptations with age and disease, being a source of potential biomarkers. However, there is no evidence on the lipid profile and cellularity at different skeletal locations in osteoarthritis patients undergoing primary hip arthroplasty.
View Article and Find Full Text PDFJ Pers Med
January 2025
Sezione di Chirurgia Protesica ad Indirizzo Robotico-Unità di Traumatologia dello Sport, Ortopedia e Traumatologia, Fondazione Poliambulanza, 25124 Brescia, Italy.
Total hip arthroplasty (THA) is a widely performed surgical procedure that has evolved significantly due to advancements in artificial intelligence (AI) and robotics. As demand for THA grows, reliable tools are essential to enhance diagnosis, preoperative planning, surgical precision, and postoperative rehabilitation. AI applications in orthopedic surgery offer innovative solutions, including automated hip osteoarthritis (OA) diagnosis, precise implant positioning, and personalized risk stratification, thereby improving patient outcomes.
View Article and Find Full Text PDFComput Struct Biotechnol J
December 2024
Department of Orthopaedic Surgery, University of Regensburg, Asklepios Klinikum, Bad Abbach, Germany.
Background: Large Language Models (LLMs) such as ChatGPT are gaining attention for their potential applications in healthcare. This study aimed to evaluate the diagnostic sensitivity of various LLMs in detecting hip or knee osteoarthritis (OA) using only patient-reported data collected via a structured questionnaire, without prior medical consultation.
Methods: A prospective observational study was conducted at an orthopaedic outpatient clinic specialized in hip and knee OA treatment.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!