We evaluated the accuracy of the needle tip representation by different imaging techniques for the guidance of facet infiltrations. For visualisation of the lumbar facet joints we used a high-field magnetic resonance tomograph (MRT) with a 2.0 Tesla field and 3.5 mm slice thickness, an open low-field magnetic resonance tomography (MRT) with an 0.064 Tesla field and 9 mm slice thickness, and IMATRON electron beam computed tomograph (EBCT) with a slice thickness of 6 mm, and a mobile C-arm fluoroscope. The study was performed on 4 human cadaveric lumber spine preparations, each of which had 8 facet joints. Under imaging control, special injection needles were placed as close as possible to the facet joint space. Following placement of he needle, all specimens were scanned with the electron beam tomograph using a slice thickness of 1.5 mm. The thin-slice study served as the gold standard. The distance between the tip of the needle and the facet joint was measured in all the images. Comparison of the different modalities with the gold standard revealed the following results: 1) median values of the absolute differences were 1.25 mm for high-field MRI, 1.35 mm for 6 mm EBCT, 2.05 mm for low-field MRI, and 2.30 mm for X-ray fluoroscopy. 2) While there was no statistically significant difference in the accuracy of tip localization between high-field MRI and 6" EBCT (p = 0.293), both systems were more precise than low-field MRI (p = 0.04) and X-ray fluoroscopy (p = 0.009). When choosing the best imaging technique, such additional factors as radiation, costs and time, must also be considered. Provided necessary radiological precautions are taken, and assuming careful pre-interventional planning, CT. EBCT and X-ray fluoroscopy are currently more effective than the expensive, time-consuming and costly magnetic resonance tomography.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1515/bmte.2000.45.9.228 | DOI Listing |
J Food Sci Technol
February 2025
Department of Biochemistry, Faculty of Science, University of Dschang, Dschang, Cameroon.
Unlabelled: Production of instant cassava tuber flour for is an appealing process because of a significant reduction in cooking time, it involves less tedious preparation, the flour has improved odor with a significant increase in shelf life, and is of better quality. However, the optimum cassava fermentation and precooking parameters; two critical unit operations in the process, as well as their effects on the quality and shelf life of the product have not been studied elaborately. The Doehlert design was employed to optimize the fermentation and the precooking processes of cassava () tuber to produce instant flour for .
View Article and Find Full Text PDFJ Int Soc Prev Community Dent
December 2024
Assistant professor, Oral and Dental Disease Research Center, Department of Operative Dentistry, Faculty of Dentistry, Zahedan University of Medical Sciences, Zahedan, Iran.
Aim: Tooth sensitivity caused by exposed dentin tubules is a common clinical problem requiring correct treatment methods. Owing to the spread of the COVID-19 virus, it has become common to use different mouthwashes, including 1.5% hydrogen peroxide (HP), before dental procedures.
View Article and Find Full Text PDFLasers Med Sci
January 2025
School of Medicine and Dentistry, Griffith University, Gold Coast, QLD, Australia.
This in-vitro study assessed the influence of the shade of human teeth on the transmission of near-infrared light. A total of 40 teeth were used. After cleaning the root surface and removing cementum, the teeth were sectioned into slices 3 mm thick, with each comprising a portion of the crown (enamel-dentine (ED)) and of the root (dentine only).
View Article and Find Full Text PDFUnlabelled: Ultrasound imaging plays an important role in the early detection and management of breast cancer. This study aimed to evaluate the imaging performance of a range of clinically-used breast ultrasound systems using a set of novel spherical lesion contrast-detail (C-D) and anechoic-target (A-T) phantoms.
Methods: C-D and A-T phantoms were imaged using a range of clinical breast ultrasound systems and imaging modes.
Curr Oncol
January 2025
Department of Radiology, Charité-Universitätsmedizin Berlin, Freie Universität Berlin, Humboldt-Universität zu Berlin and Berlin Institute of Health, Charitéplatz 1, 10117 Berlin, Germany.
Breath-hold T2-weighted half-Fourier acquisition single-shot turbo spin echo (HASTE) magnetic resonance imaging (MRI) of the upper abdomen with a slice thickness below 5 mm suffers from high image noise and blurring. The purpose of this prospective study was to improve image quality and accelerate imaging acquisition by using single-breath-hold T2-weighted HASTE with deep learning (DL) reconstruction (DL-HASTE) with a 3 mm slice thickness. MRI of the upper abdomen with DL-HASTE was performed in 35 participants (5 healthy volunteers and 30 patients) at 3 Tesla.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!