Intraoperative angiography during emergency cerebrovascular surgery, clipping operation for acute aneurysmal subarachnoid hemorrhage, is reported. For acquisition of intraoperative angiography, an exclusively developed radiolucent version of a Sugita head frame, made of engineering plastics for angiography, and an ordinary fluoroscopic unit were installed. In a radiolucent head frame, all the parts of the ordinary metallic Sugita multipurpose head frame, fixation and its accessories were made of high-molecular polymer plastics in the same size. In emergency cerebrovascular surgery, the radiolucent Sugita frame enabled us to carry out meticulous dissection and precise retraction control as the ordinary metallic system and to perform the intraoperative angiography if needed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1054/jocn.2000.0763 | DOI Listing |
J Endovasc Ther
January 2025
Department of Vascular Surgery, The Chaim Sheba Medical Center, Tel HaShomer, Ramat Gan, Israel.
Purpose: To report a case series on using a novel semi-branch feature in custom-made stent-grafts in the endovascular treatment of complex aortic aneurysms and summarize the contemporary usage of this technology.
Case Series: Four patients underwent endovascular aortic aneurysm repair (EVAR) with a custom-made semi-branch stent-graft (Semi-Branch Endovascular Aortic Aneurysm Repair [SBEVAR]). Two male patients, 75- and 76-year-old, were treated due to failed EVAR with late-type Ia endoleak, and the other two, 80- and 55-year-old male patients, due to a juxta-renal aortic abdominal aneurysm (JRAAA).
J Vasc Surg Cases Innov Tech
April 2025
Department of Radiology and Nuclear Medicine, University Teaching and Research Hospital Lucerne, Luzern, Switzerland.
Objective: The aim of this single-center case series is to demonstrate that an ultra-low dose (ULD) can be routinely achieved in the hybrid operating room in standard endovascular aortic repair (EVAR) for infrarenal abdominal aortic aneurysm by adjusting the manufacturer's predefined imaging parameters, hardware configurations and user protocols (including benchmarking).
Methods: The hybrid operating room manufacturer predefined EVAR software setup of the dose exposure control software (OPTIQ, Siemens Healthineers, Forchheim, Germany) at our university medical center was screened for possible improvements regarding radiation dose application. Tests on a water-equivalent as well as polymethyl methacrylate phantom model to assess the impact of technical settings were performed, including comparison of settings for exposure control software, different magnification, collimation configurations and detector distance.
Surg Endosc
January 2025
Department of Paediatric Surgery, SMS Medical College, Jaipur, India.
Background: Anastomotic leak (AL) is a major complication in colorectal surgery, significantly contributing to perioperative morbidity and mortality. Among strategies to prevent AL, Indocyanine Green Fluorescence Angiography (ICG-FA) has emerged as a promising method for assessing bowel perfusion intraoperatively. This systematic review evaluates the impact of ICG-FA on AL rates and other postoperative outcomes following colorectal anastomoses.
View Article and Find Full Text PDFObjective: To evaluate the impact of intrahepatic portal vein branching (IHPB)-grade assessment using preoperative CT angiography (CTA) on the surgical procedure and prognosis prediction for dogs with an extrahepatic portosystemic shunt (EHPSS).
Methods: This study involved 146 client-owned dogs with EHPSS. The shunt morphology of EHPSS and IHPB grades was determined using CTA.
Int J Cardiol Heart Vasc
February 2025
Division of Cardiovascular Medicine, Department of Medicine, China Medical University Hospital, China Medical University, Taichung 404327, Taiwan.
Background: The optimal imaging modality for selecting the device size in patients with atrial fibrillation undergoing one-stop left atrial appendage occlusion (LAAO) with concomitant pulmonary vein isolation (PVi) remains undefined. We compared preprocedural 3-dimensional computed tomography (3D CT) with intra-procedural transesophageal echocardiography (TEE) and left atrial appendage (LAA) angiography in guiding one-stage PVi and LAAO.
Methods: We measured the LAA ostium diameter using an interactive 3D CT system with a central line-based approach and compared these measurements with those from intra-procedural TEE and angiography, and the actual device size.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!