Objectives: This study was performed to determine the feasibility, accuracy and reproducibility of real-time volumetric three-dimensional echocardiography (3-D echo) for the estimation of mitral valve area in patients with mitral valve stenosis.
Background: Planimetry of the mitral valve area (MVA) by two-dimensional echocardiography (2-D echo) requires a favorable parasternal acoustic window and depends on operator skill. Transthoracic volumetric 3-D echo allows reconstruction of multiple 2-D planes in any desired orientation and is not limited to parasternal acquisition, and could thus enhance the accuracy and feasibility of calculating MVA.
Methods: In 48 patients with mitral stenosis (40 women; mean age 61 +/- 13 years) MVA was determined by planimetry using volumetric 3-D echo and compared with measurements obtained by 2-D echo and Doppler pressure half-time (PHT). All measurements were performed by two independent observers. Volumetric data were acquired from an apical view.
Results: Although 2-D echo allowed planimetry of the mitral valve in 43 of 48 patients (89%), calculation of the MVA was possible in all patients when 3-D echo was used. Mitral valve area by 3-D echo correlated well with MVA by 2-D echo (r = 0.93, mean difference, 0.09 +/- 0.14 cm2) and by PHT (r = 0.87, mean difference, 0.16 +/- 0.19 cm2). Interobserver variability was significantly less for 3-D echo than for 2-D echo (SD 0.08cm2 versus SD 0.23cm2, p < 0.001). Furthermore, it was much easier and faster to define the image plane with the smallest orifice area when 3-D echo was used.
Conclusions: Transthoracic real-time volumetric 3-D echo provides accurate and highly reproducible measurements of mitral valve area and can easily be performed from an apical approach.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/s0735-1097(00)00852-4 | DOI Listing |
Echo Res Pract
December 2024
1st Cardiology Department, General Hospital of Nikea, Agios Panteleimon, 3 D. Mantouvalou str., 18454, Athens, Greece.
J Strength Cond Res
January 2025
Laboratory of Neuromuscular Research and Active Aging, Department of Kinesiology and Sports Sciences, University of Miami, Coral Gables, Florida.
Calaway, C, Walls, K, Levitt, H, Caplan, J, Mann, B, Martinez, K, Gastaldo, R, Haq, I, and Signorile, JF. Velocity-based-training frequency impacts changes in muscle morphology, neuromuscular performance, and functional capability in persons with Parkinson's disease. J Strength Cond Res 39(1): 99-106, 2025-Velocity-based training (VBT) positively impacts muscle morphology and performance in persons with Parkinson's disease (PD); however, optimal training frequencies for VBT in patients with PD remain undetermined.
View Article and Find Full Text PDFMed Sci Sports Exerc
December 2024
Sports Technology Unit, Faculty of Sport and Health Sciences, University of Jyväskylä, Vuokatti, FINLAND.
Introduction: Resting energy expenditure (REE) may fluctuate during the menstrual cycle (MC), due to the physiological effects of estradiol (E2) and progesterone. This study examined changes in REE and metabolic hormones (leptin, ghrelin, thyroid hormones), and dietary intake in two hormonally distinct groups, naturally menstruating women (NoOC) and women using monophasic combined oral contraceptives (COC).
Methods: Measurements included REE by indirect calorimetry, body composition by bioimpedance, and blood samples for hormone analysis in the early follicular and midluteal phases of the MC in the NoOC group ( n = 38) or the active and inactive phases of the COC cycle (COC; n = 19).
IEEE Trans Ultrason Ferroelectr Freq Control
August 2024
Super-resolution ultrasound imaging using the erythrocytes (SURE) has recently been introduced. The method uses erythrocytes as targets instead of fragile microbubbles (MBs). The abundance of erythrocyte scatterers makes it possible to acquire SURE data in just a few seconds compared with several minutes in ultrasound localization microscopy (ULM) using MBs.
View Article and Find Full Text PDFBrain Imaging Behav
February 2024
Department of Medical, Surgical Sciences and Advanced Technologies "GF Ingrassia", University of Catania, Via Santa Sofia 78, 95123, Catania, Italy.
Isolated rapid eye movement (REM) sleep behavior disorder (iRBD) is a parasomnia characterized by loss of physiological atonia of skeletal muscles with abnormal behaviors arising during REM sleep. RBD is often the early manifestation of neurodegenerative diseases, particularly alpha-synucleinopathies, such as Parkinson's disease (PD). Both structural and functional neuroimaging studies suggest that iRBD might share, or even precede, some of the features commonly found in PD, although without a definitive conclusion.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!