A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Some limitations in the practical delivery of intensity modulated radiation therapy. | LitMetric

The resolution characteristics of intensity modulated beam (IMB) profiles produced by milled compensators and by multileaf collimators (MLCs) are independently investigated with respect to the primary fluence. It is shown that both methods have different characteristics in the longitudinal and lateral direction and, as a consequence, the resolutions of the longitudinal and lateral delivered IMB profiles differ. For both methods, the restrictions are identified. For compensators, the maximum slopes in the machining process, which should not be exceeded, are quantified. For MLCs, emphasis is given to the direction perpendicular to leaf movement. A number of test modulations were created and the effect of different size MLCs on the intensity profile revealed that unacceptable errors can be introduced if the profiles are heavily modulated. The production of intensity modulated radiation therapy (IMRT) beams by both machined compensators or by MLCs is limited by physical constraints. Having identified these constraints, some steps should now be taken to accommodate them either in the objective function for the calculation of the beam profiles or in the delivery system.

Download full-text PDF

Source
http://dx.doi.org/10.1259/bjr.73.872.11026861DOI Listing

Publication Analysis

Top Keywords

intensity modulated
12
modulated radiation
8
radiation therapy
8
imb profiles
8
longitudinal lateral
8
limitations practical
4
practical delivery
4
intensity
4
delivery intensity
4
modulated
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!