This study evaluated the noise attenuation of earplugs and earmuffs or their combined use against heavy weapon noise in field conditions for military personnel. The noise attenuation was measured with a miniature microphone inserted into the ear canal. The subjects (13) were tested against pink noise and against the noise of explosions and bazooka, mortar, cannon, and howitzer. The attenuation (insertion loss) was 16 to 23 dB for earplugs, 10 to 20 dB for earmuffs, and 24 to 34 dB for the combined use of plugs and muffs. The transfer function of an open ear was 5 to 7 dB when measured as the C-weighted peak level. The combined use of earplugs and earmuffs gave smaller attenuation values than expected. If the limit for the C-weighted peak level is 140 dB for unprotected ears, then protection against low-frequency noise is provided for up to 156 dB by earplugs, up to 150 dB by earmuffs, and up to 165 dB by the combined use of plugs and muffs.
Download full-text PDF |
Source |
---|
J Res Med Sci
December 2024
Department of Medical Imaging Center, Affiliated Hospital of Shandong Second Medical University, Weifang, Shandong, China.
Background: Accurate and timely assessment of tumor response after chemotherapy is crucial in clinical settings. The aim of this study was to explore the feasibility of Gemstone Spectral Imaging (GSI) for early assessment of chemotherapy responses in patients with colorectal cancer liver metastasis (CRCLM).
Materials And Methods: From October 2012 to October 2018, 46 patients (28 males and 18 females) with CRCLM received GSI followed by chemotherapy were retrospectively reviewed.
Med Phys
January 2025
Institute for Medical Engineering, Otto von Guericke University Magdeburg, Magdeburg, Germany.
Background: The success of embolization, a minimally invasive treatment of liver cancer, could be evaluated in the operational room with cone-beam CT by acquiring a dynamic perfusion scan to inspect the contrast agent flow.
Purpose: The reconstruction algorithm must address the issues of low temporal sampling and higher noise levels inherent in cone-beam CT systems, compared to conventional CT.
Methods: Therefore, a model-based perfusion reconstruction based on the time separation technique (TST) was applied.
Sci Total Environ
January 2025
Guangdong Province Hospital for Occupational Disease Prevention and Treatment, Guangzhou, Guangdong, China; Guangdong Medical University, Dongguan, Guangdong, China; Guangdong Pharmaceutical University, Guangzhou, Guangdong, China; Southern Medical University, Guangzhou, Guangdong, China; JI NAN University, Guangdong, China. Electronic address:
Background: Noise is a threat to human auditory system, hearing protection devices (HPDs) are widely used to prevent noise-induced hearing loss (NIHL). However, the role of wearing HPDs on NIHL and the complex relationship between them are still unclear. This study aims to explore such relationship and identify the associated influencing pathways.
View Article and Find Full Text PDFMicromachines (Basel)
January 2025
College of Mechanical & Electrical Engineering, Central South University, Changsha 410083, China.
In the health monitoring and safety assessments of concrete structures, ultrasonic non-destructive testing (NDT) technology has become an indispensable tool due to its non-destructive nature, efficiency, and precision. However, when used in inspecting irregular concrete surfaces, traditional planar ultrasonic transducers often encounter energy loss and signal attenuation induced by poor interface coupling, which significantly reduces the accuracy and reliability of the test results. To address this problem, this article proposes a point-contact dry coupling ultrasonic transducer solution, which enables efficient acquisition of ultrasonic signals within concrete without the need for couplants.
View Article and Find Full Text PDFBrain Sci
January 2025
Department of Otolaryngology at Unfallkrankenhaus Berlin, Charité Medical School, University of Berlin, 12683 Berlin, Germany.
Background: Previous studies have shown that multiple post-traumatic irradiations of the cochlea with near-infrared light (NIR) can significantly reduce noise-induced hearing loss. However, a single NIR pre-treatment was shown to have the same effect. Extending the pre-treatment time did not result in any further reduction in hearing loss.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!