An intense collimated beam of high-energy protons is emitted normal to the rear surface of thin solid targets irradiated at 1 PW power and peak intensity 3x10(20) W cm(-2). Up to 48 J ( 12%) of the laser energy is transferred to 2x10(13) protons of energy >10 MeV. The energy spectrum exhibits a sharp high-energy cutoff as high as 58 MeV on the axis of the beam which decreases in energy with increasing off axis angle. Proton induced nuclear processes have been observed and used to characterize the beam.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.85.2945DOI Listing

Publication Analysis

Top Keywords

intense high-energy
4
high-energy proton
4
proton beams
4
beams petawatt-laser
4
petawatt-laser irradiation
4
irradiation solids
4
solids intense
4
intense collimated
4
collimated beam
4
beam high-energy
4

Similar Publications

Tightly bound electron-hole pairs (excitons) hosted in atomically-thin semiconductors have emerged as prospective elements in optoelectronic devices for ultrafast and secured information transfer. The controlled exciton transport in such excitonic devices requires manipulating potential energy gradient of charge-neutral excitons, while electrical gating or nanoscale straining have shown limited efficiency of exciton transport at room temperature. Here, we report strain gradient induced exciton transport in monolayer tungsten diselenide (WSe) across microns at room temperature via steady-state pump-probe measurement.

View Article and Find Full Text PDF

Nonemissive Iridium(III) Solvent Complex as a Self-Reporting Photosensitizer for Monitoring Phototherapeutic Efficacy in a "Signal on" Mode.

Chem Biomed Imaging

December 2024

Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an, 710062, P. R. China.

Photodynamic therapy (PDT) has long been receiving increasing attention for the minimally invasive treatment of cancer. The performance of PDT depends on the photophysical and biological properties of photosensitizers (PSs). The always-on fluorescence signal of conventional PSs makes it difficult to real-time monitor phototherapeutic efficacy in the PDT process.

View Article and Find Full Text PDF

Design and commissioning of the PRIOR-II "proton microscope for FAIR".

Rev Sci Instrum

December 2024

Plasmaphysics Department, GSI Helmholtzzentrum für Schwerionenforschung GmbH, Planckstrasse 1, 64291 Darmstadt, Germany.

A new high energy proton radiography facility PRIOR-II (Proton Microscope for FAIR) has been designed, constructed, and successfully commissioned at the GSI Helmholtzzentrum für Schwerionenforschung (Darmstadt, Germany) pushing the technical boundaries of charged particle radiography with normal conducting magnets to the limits. The setup is foreseen to become a new and powerful user facility for carrying out fundamental science experiments in the fields of plasma and shock wave physics, material science, and medical physics. It will help address several unsolved scientific challenges, which require high-speed and precise non-invasive diagnostic methods capable of probing matter with up to 100 g/cm2 areal density.

View Article and Find Full Text PDF

Non-Flammable fluorinated gel polymer electrolyte for safe lithium metal batteries in harsh environments.

J Colloid Interface Sci

December 2024

Jiangsu Key Laboratory of Materials and Technologies for Energy Storage, College of Materials Science and Technology, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China; State Key Laboratory of Mechanics and Control for Aerospace Structures, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China.

Compared to liquid electrolytes, gel polymer electrolytes (GPEs) offer enhanced safety and represent an up-and-coming option for high-energy-density lithium metal batteries (LMBs). However, several challenges hindered the practical application of GPEs for LMBs, such as low ionic conductivity at room temperature, decomposition at high voltage, and poor interfacial compatibility with lithium anode. In this study, a non-flammable fluorinated GPE was synthesized using 2,2,2-trifluoroethyl acrylate (TFEA) and ethoxylated trimethylolpropane triacrylate (ETPTA) as precursor materials, with succinonitrile (SN) incorporated as a plasticizer and a dual-salt system of lithium bis(trifluoro-methane) sulfonimide and lithium difluoroxalate borate.

View Article and Find Full Text PDF

Objectives: Music festivals are often a source of joy, but also a risk of injury. While previous studies suggest music can relieve pain, its effect has not been tested in festival settings, nor has the effect of high-energy vs soothing music been compared. We hypothesized that guests at a heavy metal music festival would experience less pain when listening to thrash heavy metal compared to relaxing music, with the effect being influenced by music preference and increased with higher alcohol intake.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!