Background: Locked intramedullary (IM) nailing has been recognized as one of the most reliable methods for treatment of femoral shaft fractures. Although IM nails are routinely used in the treatment of these fractures, the long-term effects of retained IM nails are unknown.

Methods: Seventeen patients with radiographically documented healed fracture of femoral diaphysis after locked IM nailing technique were evaluated at a follow-up of at least 18 months postoperatively. All patients had returned to their preinjury level of function and activity before the study. The bone mineral densities (BMD) of the injured and contralateral femora were measured using dual energy x-ray absorptiometry (DEXA). BMD of symmetrical regions in the femoral neck and medial and lateral femoral cortex of the implanted and contralateral femora were compared. Postinjury muscle function was assessed from measurement of the isometric strength of six separate muscle groups (quadriceps, hamstrings, hip extensors, hip flexors, hip abductors, and hip adductors) in treated and control extremities.

Results: The average BMD of the femoral neck region of instrumented femora was 9% less than in contralateral control. Within the medial cortex, BMD of the control femora was an average of 20% greater than in the implanted side. In the lateral cortex, the difference averaged 13%. The isometric dynamometric data demonstrated a statistically significant reduction in the strength of the quadriceps of the instrumented extremities as compared with the contralateral ones. There was no significant difference in the strength of the hamstrings, hip extensors, hip flexors, abductors, or adductors. In the control extremities, the average torque generated by isometric contraction of the quadriceps was 3.45+/-1.35 times greater than by the hamstrings. Torque in extension/flexion and abduction/adduction was also observed.

Conclusion: Our data suggest that limbs with long-term retained IM nails experience a significant reduction in the femur BMD and quadriceps muscle strength. These findings may not be simply related to the implant, and further study is warranted to determine the causes of these changes.

Download full-text PDF

Source
http://dx.doi.org/10.1097/00005373-200009000-00010DOI Listing

Publication Analysis

Top Keywords

femoral shaft
8
shaft fractures
8
intramedullary nailing
8
retained nails
8
contralateral femora
8
femoral neck
8
hamstrings hip
8
hip extensors
8
extensors hip
8
hip flexors
8

Similar Publications

The anatomy of the sciatic nerve allows it to be blocked at different levels using various anesthetic approaches. However, for several reasons, performing these approaches may be challenging or disadvantageous in specific categories of patients, particularly in obese patients. The objective of this brief technical report is to describe a new technical approach to sciatic nerve block, designed to simplify the procedure for certain categories of patients and less experienced practitioners.

View Article and Find Full Text PDF

The paper presents a detailed gross anatomical description of the elements of the pelvic limb in the African green monkey and provides comparative and differential elements on pelvic limb monkey osteology. The osteometric investigation adds value to the gross morphological and radiological investigation, adjoining metric data to the gross descriptive data set. The main methodology used was the gross morphological investigation, doubled by regular osteometrical and radiographical assessments.

View Article and Find Full Text PDF

Purpose: The aim of this study was to evaluate the feasibility of using patient-specific implants (PSI) for complex shaft corrective osteotomies in multiplanar deformities of long bones in the lower extremities. Additionally, it aimed to investigate the added value of these implants by quantifying surgical accuracy on postoperative CT, comparing their outcomes to two commonly used techniques: 3D virtual visualizations and 3D-printed surgical guides.

Methods: Six tibial and femoral shaft corrective osteotomies were planned and performed on three Thiel embalmed human specimen.

View Article and Find Full Text PDF

The primary weight-bearing structure of the proximal femur, trabecular bone, has a complex three-dimensional architecture that was previously difficult to comprehensively display. This study examined the spatial architecture of trabecular struts in the coronal, sagittal, and horizontal sections of the proximal femur using 21 cases prepared with P45 sectional plasticization. The primary compressive strut (PCS) exhibited a "mushroom-like" shape with upper and lower parts.

View Article and Find Full Text PDF

Identification of subtrochanteric and femoral shaft fractures as atypical femur fractures on radiology reports.

Acta Radiol

January 2025

Department of Orthopedics and Experimental and Clinical Medicine, Faculty of Health Science, Linköping University, Linköping, Sweden.

Background: Bisphosphonate-associated stress fractures, atypical femur fractures (AFF), are a rare subgroup of femoral stress fractures. Their correct and early diagnosis is imperative for appropriate treatment.

Purpose: To investigate the sensitivity of written radiology reports to mention radiographic features of AFF, depending on the time period and academic level of the hospital.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!