Under current Department of Defense (DOD) directive, the laboratories certified to conduct urinalyis testing in support of the DOD Drug Deterrence Program are required to conduct dl-isomer analysis on all specimens that confirm at a concentration greater than 500 ng/mL methamphetamine (METH). Although the same cutoff concentration is required for amphetamine (AMP) reporting, there is no requirement for dl-isomer analysis of AMP-positive specimens. Of the 894,823 specimens screened by the Army Drug Testing Laboratory at Ft. Meade, MD during a 19-month period, 339 confirmed positive for METH. From this positive population, seven specimens failed to confirm at or above the DOD cutoff of > 20% d-isomer. One of the seven specimens contained 534 ng/mL l-AMP and was reported positive for AMP. Although 100% of the AMP was the l-isomer, under current DOD directive, this information was not passed along to the Medical Review Officers (MRO) to assist them during the interview process. Although this situation appears to be a rare event, consideration should be given to requiring dl-isomer analysis of AMP-positive specimens and forwarding this information to the MRO.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/jat/24.6.450 | DOI Listing |
J Anal Toxicol
September 2000
U.S. Army Forensic Toxicology Drug Testing Laboratory, Fort Meade, Maryland 20755, USA.
Under current Department of Defense (DOD) directive, the laboratories certified to conduct urinalyis testing in support of the DOD Drug Deterrence Program are required to conduct dl-isomer analysis on all specimens that confirm at a concentration greater than 500 ng/mL methamphetamine (METH). Although the same cutoff concentration is required for amphetamine (AMP) reporting, there is no requirement for dl-isomer analysis of AMP-positive specimens. Of the 894,823 specimens screened by the Army Drug Testing Laboratory at Ft.
View Article and Find Full Text PDFAppl Biochem Biotechnol
March 1999
Department of Biological Science and Biotechnology, Tsinghua University, Beijing, China.
Aminoacylase (EC 3.5.1.
View Article and Find Full Text PDFNihon Yakurigaku Zasshi
May 1989
Earth Chemical Co., Ltd., Hyogo, Japan.
The beneficial effect of LC-80 in the therapy for organic acidemias, especially propionic acidemia and methylmalonic acidemia, was compared with those of its optical isomers, d-carnitine chloride (d-isomer) and dl-carnitine chloride (dl-isomer) in rat liver mitochondria. LC-80 at concentrations of 5 and 10 mM did not inhibit the mitochondrial function, while the d-isomer at a concentration of 5 mM significantly reduced the respiratory control ratio (RCR) of mitochondria. In addition, the dl-isomer at concentrations of 10 and 20 mM also significantly reduced RCR in a concentration-dependent manner.
View Article and Find Full Text PDFUtilization of intravenously administered D-methionine was measured by morbidly obese subjects fed parenterally after elective gastric bypass surgery. Five patients were infused with a 25% glucose--4.25% amino acid solution containing DL-methionine, and four were treated with a 25% glucose--3.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!