Magnetic field dependence of ultracold inelastic collisions near a feshbach resonance.

Phys Rev Lett

JILA, National Institute of Standards and Technology and the University of Colorado, and the Department of Physics, University of Colorado, Boulder, Colorado 80309-0440, USA.

Published: July 2000

Inelastic collision rates for ultracold 85Rb atoms in the F = 2, m(f) = -2 state have been measured as a function of magnetic field. At 250 gauss (G), the two- and three-body loss rates were measured to be K2 = (1.87+/-0.95+/-0.19)x10(-14) cm(3)/s and K3 = (4.24(+0. 70)(-0.29)+/-0.85)x10(-25) cm(6)/s, respectively. As the magnetic field is decreased from 250 G towards a Feshbach resonance at 155 G, the inelastic rates decrease to a minimum and then increase dramatically, peaking at the Feshbach resonance. Both two- and three-body losses are important, and individual contributions have been compared with theory.

Download full-text PDF

Source
http://dx.doi.org/10.1103/PhysRevLett.85.728DOI Listing

Publication Analysis

Top Keywords

magnetic field
12
feshbach resonance
12
two- three-body
8
field dependence
4
dependence ultracold
4
ultracold inelastic
4
inelastic collisions
4
collisions feshbach
4
resonance inelastic
4
inelastic collision
4

Similar Publications

Intrinsically disordered proteins and protein regions are central to many biological processes but difficult to characterize at atomic resolution. Nuclear magnetic resonance is particularly well-suited for providing structural and dynamical information on intrinsically disordered proteins, but existing NMR methodologies need to be constantly refined to provide greater sensitivity and resolution, particularly to capitalise on the potential of high magnetic fields to investigate large proteins. In this paper, we describe how N-detected 2D NMR experiments can be optimised for better performance.

View Article and Find Full Text PDF

Background: Splenic stiffness is a potential imaging marker of portal hypertension. Normative spleen stiffness values are needed to define diagnostic thresholds.

Objective: To report stiffness measurements of the spleen in healthy children undergoing liver magnetic resonance (MR) elastography across MRI vendors and field strengths.

View Article and Find Full Text PDF

Spin Hall nano-oscillators convert DC to magnetic auto-oscillations in the microwave regime. Current research on these devices is dedicated to creating next-generation energy-efficient hardware for communication technologies. Despite intensive research on magnetic auto-oscillations within the past decade, the nanoscale mapping of those dynamics remained a challenge.

View Article and Find Full Text PDF

Objectives: Evaluating the impact of an AI-based automated cardiac MRI (CMR) planning software on procedure errors and scan times compared to manual planning alone.

Material And Methods: Consecutive patients undergoing non-stress CMR were prospectively enrolled at a single center (August 2023-February 2024) and randomized into manual, or automated scan execution using prototype software. Patients with pacemakers, targeted indications, or inability to consent were excluded.

View Article and Find Full Text PDF

Spin-orbit torque (SOT) is widely considered to be a fast and robust writing scheme for magnetic random-access memories (MRAMs). However, the requirements of field-free switching and high switching efficiency are often incompatible in SOT devices, placing a critical challenge on its improvement. Here we propose that by utilizing biaxial systems the dilemma between high-efficiency and external-field-free SOT switching can be solved intrinsically.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!