Inelastic collision rates for ultracold 85Rb atoms in the F = 2, m(f) = -2 state have been measured as a function of magnetic field. At 250 gauss (G), the two- and three-body loss rates were measured to be K2 = (1.87+/-0.95+/-0.19)x10(-14) cm(3)/s and K3 = (4.24(+0. 70)(-0.29)+/-0.85)x10(-25) cm(6)/s, respectively. As the magnetic field is decreased from 250 G towards a Feshbach resonance at 155 G, the inelastic rates decrease to a minimum and then increase dramatically, peaking at the Feshbach resonance. Both two- and three-body losses are important, and individual contributions have been compared with theory.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1103/PhysRevLett.85.728 | DOI Listing |
J Biomol NMR
January 2025
Department of Chemistry "Ugo Schiff" and Magnetic Resonance Center (CERM), University of Florence, Florence, Italy.
Intrinsically disordered proteins and protein regions are central to many biological processes but difficult to characterize at atomic resolution. Nuclear magnetic resonance is particularly well-suited for providing structural and dynamical information on intrinsically disordered proteins, but existing NMR methodologies need to be constantly refined to provide greater sensitivity and resolution, particularly to capitalise on the potential of high magnetic fields to investigate large proteins. In this paper, we describe how N-detected 2D NMR experiments can be optimised for better performance.
View Article and Find Full Text PDFPediatr Radiol
January 2025
Department of Radiology, Children's Hospital of Philadelphia, 3401 Civic Center Blvd, Philadelphia, PA, 19104, USA.
Background: Splenic stiffness is a potential imaging marker of portal hypertension. Normative spleen stiffness values are needed to define diagnostic thresholds.
Objective: To report stiffness measurements of the spleen in healthy children undergoing liver magnetic resonance (MR) elastography across MRI vendors and field strengths.
Nano Lett
January 2025
Max Planck Institute for Solid State Research, Heisenbergstr. 1, Stuttgart, 70569, Germany.
Spin Hall nano-oscillators convert DC to magnetic auto-oscillations in the microwave regime. Current research on these devices is dedicated to creating next-generation energy-efficient hardware for communication technologies. Despite intensive research on magnetic auto-oscillations within the past decade, the nanoscale mapping of those dynamics remained a challenge.
View Article and Find Full Text PDFEur Radiol
January 2025
Department of Radiology, Geneva University Hospitals, Geneva, Switzerland.
Objectives: Evaluating the impact of an AI-based automated cardiac MRI (CMR) planning software on procedure errors and scan times compared to manual planning alone.
Material And Methods: Consecutive patients undergoing non-stress CMR were prospectively enrolled at a single center (August 2023-February 2024) and randomized into manual, or automated scan execution using prototype software. Patients with pacemakers, targeted indications, or inability to consent were excluded.
Nano Lett
January 2025
School of Microelectronics, University of Science and Technology of China, Hefei 230026, People's Republic of China.
Spin-orbit torque (SOT) is widely considered to be a fast and robust writing scheme for magnetic random-access memories (MRAMs). However, the requirements of field-free switching and high switching efficiency are often incompatible in SOT devices, placing a critical challenge on its improvement. Here we propose that by utilizing biaxial systems the dilemma between high-efficiency and external-field-free SOT switching can be solved intrinsically.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!