Exposures to 1,6-hexamethylene diisocyanate during polyurethane spray painting in the U.S. Air Force.

Appl Occup Environ Hyg

Industrial Hygiene Branch, U.S. Air Force Institute for Environment, Safety and Occupational Health Risk Analysis, Brooks Air Force Base, Texas, USA.

Published: September 2000

1,6-Hexamethylene diisocyanate (HDI) exposures were measured during polyurethane enamel spray painting at four Air Force bases. Breathing zone samples were collected for HDI monomer and polyisocyanates (oligomers) using three sampling methods: NIOSH Method 5521, the Iso-Chek sampler, and the total aerosol mass method (TAMM). Exposures to HDI monomer are low when compared to current occupational exposure limits; the highest 8-hr time-weighted average (TWA) exposure found was 3.5 micrograms/m3, below the American Conference of Governmental Industrial Hygienists (ACGIH) threshold limit value (TLV) of 34 micrograms/m3. HDI oligomer levels were higher; mean task exposures indicated by either the Iso-Chek sampler or TAMM are above the Oregon ceiling limit of 1 mg/m3. Eight-hour TWA exposures, however, were much lower, with only one exceeding the Oregon standard of 0.5 mg/m3. Poor worker practices commonly observed during this study included: standing in downwind positions so paint overspray passed through breathing zones; spraying toward other painters; and using excessive paint spray gun air cap pressures. Workers should stand in upwind orientation relative to the aircraft being painted, causing overspray to move away from the painter's breathing zone; adjust their position to prevent spraying other painters or limit paint application to one worker at a time; and use air cap pressure gauges prior to spraying to limit spray gun air cap pressures and reduce paint overspray generation rates. These improved techniques will result in reduced worker exposures to isocyanates.

Download full-text PDF

Source
http://dx.doi.org/10.1080/10473220050110121DOI Listing

Publication Analysis

Top Keywords

air cap
12
16-hexamethylene diisocyanate
8
spray painting
8
painting air
8
air force
8
breathing zone
8
hdi monomer
8
iso-chek sampler
8
paint overspray
8
spraying painters
8

Similar Publications

Periprosthetic joint infections occur in 1-2% of all patients undergoing prosthetic joint surgeries. Although strong efforts have been made to reduce infection rates, conventional therapies like one- or two-stage revisions have failed to lower the infection rates. Cold atmospheric plasma (CAP) has shown promising results in reducing bacterial loads on surfaces.

View Article and Find Full Text PDF

Protocol for the enhanced management of multimorbid patients with COPD and severe asthma: role of indoor air quality.

BMJ Open Respir Res

January 2025

Fundació de Recerca Clínic Barcelona - Institut d'Investigacions Biomèdiques August Pi i Sunyer (FRCB-IDIBAPS), Barcelona, Spain.

Introduction: Reducing unplanned hospital admissions in chronic patients at risk is a key area for action due to the high healthcare and societal burden of the phenomenon. The inconclusive results of preventive strategies in patients with chronic obstructive respiratory disorders and comorbidities are explainable by multifactorial but actionable factors.The current protocol (January 2024-December 2025) relies on the hypothesis that intertwined actions in four dimensions: (1) management change, (2) personalisation of the interventions based on early detection/treatment of acute episodes and enhanced management of comorbidities, (3) mature digital support and (4) comprehensive assessment, can effectively overcome most of the limitations shown by previous preventive strategies.

View Article and Find Full Text PDF

The transition to net zero emissions requires the capture of carbon dioxide from industrial point sources, and direct air capture (DAC) from the atmosphere for geological storage. Dissolved CO has reactivity to rock core, and while the majority of previous studies have concentrated on reservoir rock or cap-rock reactivity, the underlying seal formation may also react with CO. Drill core from the underlying seal of a target CO storage site was reacted at in situ conditions with pure CO, and compared with an impure CO stream with SO, NO and O that could be expected from hard to abate industries.

View Article and Find Full Text PDF

Introduction: Cancer is a leading cause of death in the Americas. Colorectal cancer is the third most common cancer, while stomach cancer is the sixth most common cancer worldwide. Tobacco and alcohol consumption, unhealthy diet, physical inactivity and air pollution are risk factors for these cancers.

View Article and Find Full Text PDF

Cold atmospheric plasma (CAP) has antimicrobial properties and is also known to stimulate the immune system. These properties could be useful for the development of a novel therapeutic or preventive strategy against respiratory infections in the upper respiratory tract (URT) such as ventilator-associated pneumonia (VAP) without inducing an immune overreaction. This study investigated the cellular responses of polymorphonuclear neutrophils (PMNs) after exposure to CAP in a three-dimensional (3D) model of the URT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!