Neuroretinal rim measurement error using PC-based stereo software.

Clin Exp Ophthalmol

Lions Eye Institute, Centre for Ophthalmology and Visual Science, University of Western Australia, Nedlands, Australia.

Published: June 2000

The neuroretinal rims of a set of glaucoma patients were measured using digitized stereo photographs, to determine the reproducibility of computerized stereo measurements of the neuroretinal rim. Each rim was measured five times at 18 locations, with measurement error (ME) defined as the mean of standard deviations of each set of measurements. The following ME were determined: (i) inter-sessional variability (n = 27 right and 24 left eyes, at t1 and t2); (ii) inter-assessor variability (n = 9, 2 assessors); and (iii) variability after colour adjustment algorithms were applied (n = 15). The results were as follows: (i) inter-sessional variability was 3.41+/-1.08 for t1 and 3.22+/-0.84 for t2; (ii) there was a significant difference between the two assessors, although the ME was still low; and (iii) there was no significant differences between the ME of unadjusted and adjusted images. With a measurement error of up to 11% of rim width, these results show that lowcost rim measurements can be made using PC-based software.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1442-9071.2000.00298.xDOI Listing

Publication Analysis

Top Keywords

measurement error
12
neuroretinal rim
8
inter-sessional variability
8
rim measurement
4
error pc-based
4
pc-based stereo
4
stereo software
4
software neuroretinal
4
neuroretinal rims
4
rims set
4

Similar Publications

Motion-Compensated Multishot Pancreatic Diffusion-Weighted Imaging With Deep Learning-Based Denoising.

Invest Radiol

January 2025

From the Department of Radiology, Stanford University, Stanford, CA (K.W., M.J.M., A.M.L., A.B.S., A.J.H., D.B.E., R.L.B.); Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (K.W.); GE HealthCare, Houston, TX (X.W.); GE HealthCare, Boston, MA (A.G.); and GE HealthCare, Menlo Park, CA (P.L.).

Objectives: Pancreatic diffusion-weighted imaging (DWI) has numerous clinical applications, but conventional single-shot methods suffer from off resonance-induced artifacts like distortion and blurring while cardiovascular motion-induced phase inconsistency leads to quantitative errors and signal loss, limiting its utility. Multishot DWI (msDWI) offers reduced image distortion and blurring relative to single-shot methods but increases sensitivity to motion artifacts. Motion-compensated diffusion-encoding gradients (MCGs) reduce motion artifacts and could improve motion robustness of msDWI but come with the cost of extended echo time, further reducing signal.

View Article and Find Full Text PDF

In order to address many issues, such as the inconsistent and unreliable seeding process in traditional mechanical garlic seed metering systems (SMS), as well as the lack of ability to monitor the effectiveness of the seeding, a highly accurate electric-driven metering system (EDMS) was developed and created specifically for garlic seed planters. This study provided a description of the overall structure and functioning principle, as well as an analysis of the mechanism for smooth transit and delivery. A combination of an infrared (IR) sensor, Arduino Mega board, stepper motor, speed sensor, and a Wi-Fi module was employed to operate the EDMS, as well as monitor and count the quantity of garlic seeds during the planting process and determine the qualified rate (QR) and missing rate (MR).

View Article and Find Full Text PDF

In this study, we aimed to reveal the trends of self-measured blood pressure (SMBP) and SMBP-derived indices during pregnancy and the postpartum period. The Babies and Their Parents Longitudinal Observation in Suzuki Memorial Hospital in the Intrauterine Period (BOSHI) Study is a prospective cohort study in Japan. Participants were instructed to measure SMBP daily during pregnancy and for 1 month after delivery.

View Article and Find Full Text PDF

Wearable devices enable the continuous monitoring of physical activity (PA) but generate complex functional data with poorly characterized errors. Most work on functional data views the data as smooth, latent curves obtained at discrete time intervals with some random noise with mean zero and constant variance. Viewing this noise as homoscedastic and independent ignores potential serial correlations.

View Article and Find Full Text PDF

Background: No questionnaire is currently available for use in patients with shoulder pain in an Indonesian-speaking population. This study aimed to translate the Oxford Shoulder Score (OSS) into Indonesian and assess its validity and reliability for use in Indonesian-speaking patients with shoulder pain.

Methods: After a forward and backward translation procedure, the validity and reliability of the questionnaire were investigated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!