A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Surgical management of malignant melanoma using dynamic lymphoscintigraphy and gamma probe-guided sentinel lymph node biopsy: the Emory experience. | LitMetric

Sentinel lymph node (SLN) biopsy is revolutionizing the surgical management of primary malignant melanoma. It allows accurate nodal staging which targets patients who may benefit from regional lymphadenectomy and systemic therapy. This is a retrospective review of patients treated at Emory University for stage I and II malignant melanoma with gamma probe-guided SLN biopsy from 1/1/94 to 6/30/98. Three hundred sixty patients (males 228, females 132) were identified. Primary melanoma sites included: head and neck 58, trunk 148, and extremities 154 (upper 71, lower 83). Primary tumor staging was T1 9, T2 134, T3 153, and T4 64. SLNs were successfully identified in 99.7 per cent of patients and 98.9 per cent of nodal basins mapped. In 275 (76.6%) cases a single draining nodal basin was identified. In 84 (23.3%) cases there were multiple draining nodal basins. Positive SLNs were identified in 63 patients (17.5%). SLN positivity by tumor staging was T1 0 per cent, T2 9.0 per cent, T3 22.2 per cent, and T4 26.6 per cent. The overall recurrence rate was 11.9 per cent. Recurrences by SLN status were SLN+, 27 per cent, and SLN-, 8.8 per cent. Regional recurrence occurred in 7 (2.4%) of the 297 with negative SLN biopsies and 7 (11.1%) of the 63 with positive SLN biopsies. Dynamic lymphoscintigraphy and gamma probe-guided SLN localization was successful in more than 98 per cent of cases. Patients with negative SLN biopsies have a low risk of recurrence.

Download full-text PDF

Source

Publication Analysis

Top Keywords

malignant melanoma
12
gamma probe-guided
12
sln biopsies
12
cent
10
surgical management
8
dynamic lymphoscintigraphy
8
lymphoscintigraphy gamma
8
sentinel lymph
8
lymph node
8
sln
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!