A highly efficient direct injection/on-line guard cartridge extraction/tandem mass spectrometry (DI-GCE/MS/MS) method utilizing electrospray polarity switching was developed for the simultaneous detection of probe substrates and marker metabolites of seven human hepatic cytochrome P450 (CYP) isozymes: CYP1A2, 2A6, 3A4, 2C9, 2C19, 2D6 and 2E1. Microsomal incubations were terminated with formic acid, centrifuged, and the resulting supernatants were injected for analysis by DI-GCE/MS/MS. This method employed an extremely short C(18) cartridge (4 mm in length) which allowed rapid cleanup of sample matrices while retaining the analytes an appropriate time (2. 0-2.2 min). From 1.5 to 2.7 min the effluent was directed to the mass spectrometer for detection otherwise diverted to waste. As a result of the efficient on-line extraction, matrix (e.g., salts and proteins) suppression was minimized. In addition, no visible source contamination was observed and system performance (chromatographic and mass spectrometric) did not significantly deteriorate after 500 consecutive injections. Electrospray polarity switching was strategically executed on a Micromass Quattro II mass spectrometer by establishing dummy ion transitions to protect the analytes from the interference of the overwhelming noise which was unavoidable for the first transition scanned following each polarity switch. This unique strategy led to the simultaneous detection of seven CYP probe substrates and seven corresponding marker metabolites (12 by positive mode and 2 by negative mode).
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1002/1097-0231(20000915)14:17<1619::AID-RCM71>3.0.CO;2-2 | DOI Listing |
Rev Sci Instrum
January 2025
Max Planck Institute for Chemical Energy Conversion, Mülheim an der Ruhr 45470, Germany.
X-ray spectroscopies are uniquely poised to describe the geometric and electronic structure of metalloenzyme active sites under a wide variety of sample conditions. UV/Vis (ultraviolet/visible) spectroscopy is a similarly well-established technique that can identify and quantify catalytic intermediates. The work described here reports the first simultaneous collection of full in situ UV/Vis and high-energy resolution fluorescence detected x-ray absorption spectra.
View Article and Find Full Text PDFACS Sens
January 2025
Materials Interfaces Center, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, P. R. China.
Over recent years, the LUMinescent AntiBody Sensor (LUMABS) system, utilizing bioluminescence resonance energy transfer (BRET), has emerged as a highly effective method for antibody detection. This system incorporates NanoLuc (Nluc) as the donor and fluorescent protein (FP) as the acceptor. However, the limited Stokes shift of FP poses a challenge, as it leads to significant spectral cross-talk between the excitation and emission spectra.
View Article and Find Full Text PDFJMIR Form Res
January 2025
Limburg Clinical Research Center/Mobile Health Unit, Faculty of Medicine and Life Sciences, Hasselt University, Hasselt, Belgium.
Background: Consumer-oriented wearable devices (CWDs) such as smartphones and smartwatches have gained prominence for their ability to detect atrial fibrillation (AF) through proprietary algorithms using electrocardiography or photoplethysmography (PPG)-based digital recordings. Despite numerous individual validation studies, a direct comparison of interdevice performance is lacking.
Objective: This study aimed to evaluate and compare the ability of CWDs to distinguish between sinus rhythm and AF.
Purpose: With the widespread introduction of dual energy computed tomography (DECT), applications utilizing the spectral information to perform material decomposition became available. Among these, a popular application is to decompose contrast-enhanced CT images into virtual non-contrast (VNC) or virtual non-iodine images and into iodine maps. In 2021, photon-counting CT (PCCT) was introduced, which is another spectral CT modality.
View Article and Find Full Text PDFAppl Spectrosc
January 2025
School of Mathematics Physics and Finance, Anhui Polytechnic University, Wuhu, China.
A compact dual-gas sensor based on the two near-infrared distributed feedback diode lasers and a multipass cell has been established for the simultaneous measurement of methane (CH) and acetylene (CH). The time division multiplexing calibration-free direct absorption spectroscopy is used to eliminate the cross interference in the application of multicomponent gas sensors. A wavelength stabilization technique based on the proportion integration differentiation feedback control is developed to suppress laser wavelength drift and an H-infinity (H) filter algorithm to reduce the system noise.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!