Free flow electrophoresis device for continuous on-line separation in analytical systems. An application in biochemical detection.

Anal Chem

Division of Analytical Chemistry, Leiden/Amsterdam Center for Drug Research, Leiden University, The Netherlands.

Published: August 2000

A free flow electrophoresis (FFE) device was developed for continuous electrophoretic separation of charged compounds and implemented in a continuous flow biochemical detection (BCD) system. These continuous separation characteristics make FFE well suitable for online implementation in a chromatographic or flow injection analysis system, in which an additional separation step of charged compounds is desired. In a heterogeneous biochemical flow assay for the determination of biotin, an analyte zone reacts with an excess of an affinity protein. Subsequently, the free binding sites of the affinity protein react with an excess of fluorescein-labeled ligand. Free and affinity protein-bound label are separated on the FFE device prior to fluorescence detection of the separated fractions. Biotin and streptavidin were chosen as, respectively, model ligand and affinity protein. Since all the compounds that are involved possess different electrophoretic properties, quantitative analysis is performed after completely separating the fluorescent affinity complex and labeled biotin in the FFE device within 2 min. Since the device is optically transparent, the separated zones can be detected in the separation compartment, using laser-induced fluorescence. The applicability of the BCD-FFE system in combination with a HPLC separation is demonstrated in the bioanalysis of biotin in human urine at the micromole per liter level.

Download full-text PDF

Source
http://dx.doi.org/10.1021/ac991202kDOI Listing

Publication Analysis

Top Keywords

ffe device
12
affinity protein
12
free flow
8
flow electrophoresis
8
biochemical detection
8
charged compounds
8
separation
6
device
5
affinity
5
free
4

Similar Publications

Background: We aim to study the association between spasticity and active range of motion (ROM) during four repetitive functional tasks such as cone stacking (CS), fast flexion-extension (FFE), fast ball squeezing (FBS), and slow ball squeezing (SBS), and predicted spasticity models.

Methods: An experimental study with control and stroke groups was conducted in a Medical Center. A total of sixty-four participants, including healthy control ( = 22; average age (years) = 54.

View Article and Find Full Text PDF

Initial clinical experience of atrial fibrillation ablation guided by a cryoballoon-compatible, magnetic-based circular catheter.

J Cardiovasc Electrophysiol

January 2024

Division of Cardiology, Banner - University Medical Center Phoenix, University of Arizona, College of Medicine, Phoenix, Arizona, USA.

Introduction: The circular catheter compatible with current cryoballoon system for atrial fibrillation (AF) ablation is exclusively sensed by impedance-based electro-anatomical mapping (EAM) system, limiting the accuracy of maps. We aim to investigate the feasibility and safety of a magnetic-based circular mapping catheter for AF ablation with cryoballoon.

Methods: Nineteen consecutive patients who underwent pulmonary vein isolation (PVI) with cryoballoon for paroxysmal or persistent AF were included.

View Article and Find Full Text PDF

The fabrication of high-performance microscale devices in substrates with optimal material properties while keeping costs low and maintaining the flexibility to rapidly prototype new designs remains an ongoing challenge in the microfluidics field. To this end, we have fabricated a micro free-flow electrophoresis (µFFE) device in cyclic olefin copolymer (COC) via hot embossing using a PolyJet 3D-printed master mold. A room-temperature cyclohexane vapor bath was used to clarify the device and facilitate solvent-assisted thermal bonding to fully enclose the channels.

View Article and Find Full Text PDF

The broadening of analyte streams, as they migrate through a free-flow electrophoresis (FFE) channel, often limits the resolving power of FFE separations. Under laminar flow conditions, such zonal spreading occurs due to analyte diffusion perpendicular to the direction of streamflow and variations in the lateral distance electrokinetically migrated by the analyte molecules. Although some of the factors that give rise to these contributions are inherent to the FFE method, others originate from non-idealities in the system, such as Joule heating, pressure-driven crossflows, and a difference between the electrical conductivities of the sample stream and background electrolyte.

View Article and Find Full Text PDF

Can disposable masks be worn more than once?

Ecotoxicol Environ Saf

September 2022

Public Health and Environmental Systems Division, Center for Public Health and Environmental Assessment, Office of Research and Development, US Environmental Protection Agency, Research Triangle Park, NC, USA.

Disposable facemasks are a primary tool to prevent the transmission of SARS-COV-2 during the COVID-19 pandemic. However, plastic waste generated from their disposal represents a significant environmental problem that can be reduced by maximizing the service life of disposable masks. We evaluated the effect of repeated wearing on the fitted filtration efficiency (FFE) of N95, KF94, KN95, and procedure/surgical masks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!