A three-dimensional finite difference time domain model was developed where the high pass birdcage coil and the imaged object are analysed as a single unit. A study was performed comparing linear, conventional quadrature, and four-port excitation at 64 MHz and 200 MHz for different coil loadings, namely muscle phantoms and an anatomically detailed human head model. A phase array concept was utilized to excite the birdcage coil in four ports. Two phase conditions were analyzed, the simple fixed phase and the variable phase. At 200 MHz, compared to the conventional quadrature drive, the four-port drive reduces the effects of the tissue-coil interactions leading to more uniform currents on the coil legs and consequently to a better B(1) field homogeneity. Also at 200 MHz, driving the coil in four ports provides an SAR distribution with peak values that are significantly less than those with linear or quadrature excitations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/s0730-725x(00)00143-0DOI Listing

Publication Analysis

Top Keywords

200 mhz
12
finite difference
8
difference time
8
time domain
8
birdcage coil
8
conventional quadrature
8
coil ports
8
coil
5
application finite
4
domain method
4

Similar Publications

A Hybrid Vacuum Flange RF Oscillator for Low-Cost Mass Spectrometry.

J Am Soc Mass Spectrom

January 2025

Mund-Lagowski Department of Chemistry and Biochemistry, Bradley University, Peoria, Illinois 61625, United States.

In this communication we report the construction of a printed circuit board which mounts directly to the vacuum chamber of a mass spectrometer and produces the RF waveforms needed by many nonmass-selective devices such as ion guides and ion funnels. Our device is designed to replace a standard KF40 flange, can maintain vacuum chamber pressures of less than 10 Torr, and contains the circuitry of the open-source Wisconsin Oscillator RF power supply to generate RF waveforms of 1-4 MHz and up to 200 V. In this iteration of the Wisconsin Oscillator, we also introduce a variable resistor to control the output RF amplitude and show that its ion transmission capabilities are identical to those provided by commercial RF power supplies.

View Article and Find Full Text PDF

In this paper, the dielectric behaviour of coconut oil within the frequency range 100 kHz to 30 MHz between temperature 30 °C-50 °C has been observed. The measured values of the dielectric constant and dielectric loss show notable variation with frequency and temperature for pure coconut oil. It is noticed that the dielectric constant (՛) and dielectric loss (՛՛) of coconut oil decreases with increasing temperature.

View Article and Find Full Text PDF

A recent advancement in distributed sensing known as the time-expanded phase-sensitive optical time-domain reflectometry (TE Φ-OTDR) addresses the trade-off between spatial resolution and detection bandwidth, enabling centimeter-scale resolution alongside RF detection bandwidth in the order of MHz. To date, TE Φ-OTDR approaches extract the fiber response from the first Nyquist zone (NZ). In this Letter, we propose a post-processing strategy to enhance the SNR by spectrally averaging different NZs.

View Article and Find Full Text PDF

Gas bubbles, commonly used in medical ultrasound (US), witness advancements with nanobubbles (NB), providing improved capabilities over microbubbles (MB). NBs offer enhanced penetration into capillaries and the ability to extravasate into tumors following systemic injection, alongside prolonged circulation and persistent acoustic contrast. Low-frequency insonation (<1 MHz) with NBs holds great potential in inducing significant bioeffects, making the monitoring of their acoustic response critical to achieving therapeutic goals.

View Article and Find Full Text PDF

Complementary transistors are critical for circuits with compatible input/output signal dynamic range and polarity. Organic electronics offer biocompatibility and conformability; however, generation of complementary organic transistors requires introduction of separate materials with inadequate stability and potential for tissue toxicity, limiting their use in biomedical applications. Here, we discovered that introduction of source/drain contact asymmetry enables spatial control of de/doping and creation of single-material complementary organic transistors from a variety of conducting polymers of both carrier types.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!