Background And Objectives: A study using scanning electron microscopy showed that although the laminas forming the dura mater are concentric and parallel to the surface of the medulla, the fiber layers' orientations are different in each sub-lamina, dispelling the conventional knowledge that all the fibers of the dura are arranged in a parallel direction. Thus, this study evaluated the dural lesions produced by Whitacre and Quincke spinal needles in the external and internal surface of the dura mater of the lower spine area in an attempt to gain more insight into the pathophysiology of postdural puncture headaches (PDPH).

Methods: The T11-L4 dural membranes from 5 fresh (immediately after extraction of organs for transplantation), male patients declared brain dead, ages 23, 46, 48, 55, and 60 years, were excised by anterior laminectomy. Morphologic orientation of the membrane and normal pH were maintained with an apparatus designed for this purpose. One hundred punctures (20 on each sample) at 90-degree angles were done with a new needle each time, 50 with 25-gauge Whitacre and 50 with 25-gauge Quincke needles. Half of the punctures with the Quincke needles were done with the bevel in parallel direction to the axis of the spinal cord, and the rest with the bevel perpendicular to it. Fixation in solutions of 2.5% glutaraldehyde phosphate buffer, followed by dehydration with acetone, was done 15 minutes after the punctures. After acetone was removed at ideal conditions of temperature and pressure, the specimens were then metallized with carbon followed by gold and inspected under a scanning electron microscope.

Results: Twenty-five of the Whitacre and 23 of the Quincke punctures were found for evaluation. There were no differences in the cross-sectional area of the punctures produced by the Whitacre or Quincke needles on the dura. The area of the dural lesions produced by 25-gauge Quincke needles, 15 minutes after they have been withdrawn, was 0.023 mm2 (confidence interval [CI] 95%, 0.015 to 0.027) in the external aspect (epidural surface) and 0.034 mm2 (CI 95%, 0.018 to 0.051) in the internal aspect (arachnoid surface) of the dural sac. The area of the lesions produced by the 25-gauge Whitacre needles was 0.026 mm2 (CI 95%, 0.019 to 0.032) and 0.030 mm2 (CI 95%, 0.025 to 0.036) in the external and internal surfaces of the dural sac, respectively. There were no significant differences in the cross-sectional areas of the punctures produced by the 25-gauge Whitacre or 25-gauge Quincke needles. Moreover, with Quincke needles the dural lesions closed in an 88.3% (CI 95%, 86.3 to 92.4) and 82.7% (CI 95%, 74.1 to 90.9) of their original sizes in the epidural and arachnoid surfaces, respectively. With Whitacre needles, the closure occurred in an 86.8% (CI 95%, 83.8 to 90.3) and 84.8% (CI 95% 81.7 to 87.3) in the dural and arachnoid surfaces, respectively. However, there were differences in the morphology of the lesions. The Whitacre needles produced coarse lesions with significant destruction in the dura's fibers while the Quincke needles produced a 'U'-shaped lesion (flap) that mimics the opened lid of a tin can, regardless of the tip's direction.

Conclusions: The needles produced lesions in the dura with different morphology and characteristics. Lesions with the Quincke needles resulted in a clean-cut opening in the dural membrane while the Whitacre needle produced a more traumatic opening with tearing and severe disruption of the collagen fibers. Thus, we hypothesized that the lower incidence of PDPH seen with the Whitacre needles may be explained, in part, by the inflammatory reaction produced by the tearing of the collagen fibers after dural penetration. This inflammatory reaction may result in a significant edema which may act as a plug limiting the leakage of cerebrospinal fluid.

Download full-text PDF

Source
http://dx.doi.org/10.1053/rapm.2000.7622DOI Listing

Publication Analysis

Top Keywords

quincke needles
32
whitacre needles
20
dural lesions
16
lesions produced
16
produced 25-gauge
16
25-gauge quincke
16
needles
15
scanning electron
12
whitacre quincke
12
25-gauge whitacre
12

Similar Publications

Article Synopsis
  • This study investigated how different needle types and sizes for spinal anesthesia affect the optic nerve sheath diameter (ONSD) in patients undergoing lower leg orthopedic surgery.
  • A total of 146 patients were analyzed across three needle groups, with ONSD measured at five different time points before and after surgery.
  • While most measurements showed no significant differences between groups, the 27-gauge Quincke needle produced higher ONSD values post-tourniquet release, indicating changes in intracranial pressure during the procedure.
View Article and Find Full Text PDF

Background and objectives Spinal anesthesia (SA) has become a preferred anesthetic technique for elective cesarean sections due to its rapid onset, profound sensory and motor blockade, and minimal impact on the newborn. It lowers the risk of development of thrombus in the veins and pulmonary vessels and permits early ambulation. The most popular technique used to reach the subarachnoid space is the midline technique, though it can be challenging to use in some cases, including those involving elderly patients with degenerative abnormalities in the vertebral column, patients who are unable to flex the vertebral column, noncooperative patients, and hyperesthetic patients.

View Article and Find Full Text PDF

Introduction: Interlaminar epidural steroid injections (ILESIs) are mainstay in the management of low back, neck and radicular pain and are a commonly performed pain management procedure in the United States. Our survey aims to provide an update in practice patterns of ILESIs among interventional pain physicians.

Methods: We distributed a 91-item survey nationwide to private and academic interventional pain physicians who perform epidural steroid injections (ESIs).

View Article and Find Full Text PDF
Article Synopsis
  • Needle trauma is commonly linked to peripheral nerve damage, but the occurrence of postblock dysfunction is rare, prompting a study to examine this relationship.
  • A cadaveric study involved puncturing median and ulnar nerves with various needles, assessing the extent and type of fascicular injury through histological analysis.
  • Out of 400 punctures examined, only three fascicular injuries were identified, all caused by 15° beveled needles, indicating that needle-induced injuries are infrequent and unlikely to account for postblock neurological issues.
View Article and Find Full Text PDF

Background: C-section is usually performed under spinal anesthesia also known as a subarachnoid block (SAB) over general anesthesia. Because of the lesser amount of dose used, there is a lower risk of local anesthetic toxicity and minimal transfer of drugs to the fetus. Obstetric patients have a higher risk of having post-dural puncture headache (PDPH).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!