An inflammatory response due to bioincompatibility of extracorporeal circuits is a major clinical issue during cardiopulmonary bypass (CPB). By using a swine model, we determined whether new polymer-coated circuits, the blood-contacting surfaces of which are coated with poly(2-methoxyethylacrylate) (PMEA), would reduce the inflammatory response during CPB. Plasma bradykinin levels and the percentages of CD35-positive monocytes in PMEA-coated circuits were significantly lower than those in uncoated circuits during CPB. The amount of proteins adsorbed on the PMEA-coated circuits was significantly lower than that on the uncoated circuits (0.30 microg/cm2 versus 3.42 microg/ cm2). Almost no IgG, IgM, or C3c/d was detected in proteins adsorbed on the PMEA-coated circuits although these proteins were clearly detected in proteins adsorbed on the uncoated circuits. We concluded that PMEA coating could reduce complement activation during CPB by suppressing the adsorption of IgG and IgM, which activate C3 via the classical pathway, on the surface of the circuits.

Download full-text PDF

Source
http://dx.doi.org/10.1046/j.1525-1594.2000.06520.xDOI Listing

Publication Analysis

Top Keywords

pmea-coated circuits
12
uncoated circuits
12
proteins adsorbed
12
circuits
10
extracorporeal circuits
8
cardiopulmonary bypass
8
inflammatory response
8
circuits lower
8
lower uncoated
8
adsorbed pmea-coated
8

Similar Publications

Several coating techniques for extracorporeal circulation have been developed to reduce the systemic inflammatory response during cardiopulmonary bypass (CPB). We compared the clinical effectiveness and biocompatibility of poly-2-methoxyethylacrylate (PMEA)- and heparin-coated CPB circuits in total aortic arch replacement (TAR) with the prolonged use of the bypass technique. Twenty patients who underwent elective TAR were divided randomly into two equal groups: group P (n = 10) to use PMEA-coated circuits and group H (n = 10) to use heparin-coated circuits.

View Article and Find Full Text PDF

Object: We compared the clinical effectiveness and biocompatibility of poly-2-methoxyethyl acrylate (PMEA)-coated and heparin-coated cardiopulmonary bypass (CPB) circuits in a prospective pediatric trial.

Methods: Infants randomly received heparin-coated (n=7) or PMEA-coated (n=7) circuits in elective pediatric cardiac surgery with CPB for ventricular septum defects. Clinical and hematologic variables, respiratory indices and hemodynamic changes were analyzed perioperatively.

View Article and Find Full Text PDF

Objective: The aim of this study was to compare the biocompatibility of a new Senko E-Ternal coating (SEC) for cardiopulmonary bypass (CPB) circuits with the well-established poly-2-methoxyethyl acrylate (PMEA) coating.

Methods: Forty patients undergoing aortic valve replacement were randomly assigned to either an SEC-coated group (n = 20) or a PMEA-coated group (n = 20). Clinical data and the following markers were analyzed: platelet count, platelet factor (PF) 4, fibrinogen, fibrinogen degradation products (FDPs), antithrombin III (AT III), thrombin-antithrombin complex (TAT), plasminogen, complement hemolytic activity (CH50), complement 3 (C3) and interleukin-6 (IL-6).

View Article and Find Full Text PDF

Purpose: The use of aprotinin in cardiac surgery is associated with overriding safety concerns. Therefore, there is increased research on alternatives. This study investigated the relative benefits of strategic leukofiltration on polymer-coated extracorporeal circuits (ECC), aprotinin, and combined therapy in high-risk patients.

View Article and Find Full Text PDF

A randomized open-heart surgery study comprising 30 patients was undertaken to compare the biocompatibility of Phisio-(phosphorylcholine) and PMEA-(poly-2-methoxyethyl acrylate) coated cardiopulmonary bypass (CPB) circuits and to assess the initial complement pathway activation during open-heart surgery. Blood samples were obtained at five time points, from the start of surgery to 24 hours postoperatively. The following analyses were performed: haemoglobin, lactate dehydrogenase, leukocyte and platelet counts, myeloperoxidase and neutrophil-activating peptide-2, thrombin-anti-thrombin complexes, syndecan-1 and the complement activation products C1rs-C1-inhibitor complexes, C4bc, C3bc, C3bBbP and the terminal complement complex (TCC).

View Article and Find Full Text PDF