Background: Although the male condom provides a reliable means of preventing HIV transmission, a broader choice of methods is required particularly in circumstances where the negotiation of condom use is difficult. Development of new products that may be effective as topical vaginal microbicides is the focus of a great deal of research activity currently. The novel agent PRO 2000, a naphthalene sulphonate derivative with in vitro activity against HIV and other sexually transmissible pathogens, is one such compound. We have studied the local and systemic safety and tolerance of a vaginal gel formulation of this agent at two concentrations (0.5% and 4%) over a 2 week period of daily exposure in two cohorts of healthy sexually abstinent women (one in London, UK, and the other in Antwerp, Belgium).

Methods: This was a randomised, placebo controlled, double blind, three arm clinical trial conducted on two sites. Macroscopic evidence of genital epithelial changes was sought using colposcopy and evidence of microscopic inflammation was acquired using high vaginal biopsy from predetermined sites (UK cohort only). Blood levels of PRO 2000 were measured and laboratory safety tests, including coagulation screens, were performed. The impact on vaginal ecology was also assessed.

Results: 73 women were enrolled across both sites (36 UK, 37 Belgium); 24, 24, 25 in the 4%, 0.5%, and placebo groups respectively. Of these, 70 completed 2 weeks' exposure to the study gel. Three (all in the 4% group) withdrew owing to adverse events which were possibly or probably gel related. Cervicovaginal abrasion was seen colposcopically in three subjects after 14 days of gel use (two in the 4% group and one in the placebo group). Genital ulceration was not seen during gel use in any of the subjects who completed the study. Histological evaluation of vaginal biopsy samples (36 women only) showed evidence of increased inflammatory signs in one participant of the 4.0% group. One volunteer in the placebo group had moderate inflammation at screening and at follow up. Severe inflammation was not seen among any of the subjects tested. Plasma levels of PRO 2000 and laboratory safety tests showed no evidence of systemic absorption. No impact was seen on normal vaginal ecology in the UK cohort where samples were taken 12 hours after the last gel application.

Conclusion: In this phase I study PRO 2000 gel was found to be generally well tolerated with promising local and systemic safety profiles. The 0.5% gel was better tolerated than the 4% gel as fewer genital epithelial adverse events were seen in the former. Phase II studies are about to begin in sexually active women.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1758286PMC
http://dx.doi.org/10.1136/sti.76.2.126DOI Listing

Publication Analysis

Top Keywords

pro 2000
20
gel
9
phase study
8
healthy sexually
8
local systemic
8
systemic safety
8
genital epithelial
8
vaginal biopsy
8
levels pro
8
laboratory safety
8

Similar Publications

PRO-2000 exhibits SARS-CoV-2 antiviral activity by interfering with spike-heparin binding.

Antiviral Res

September 2023

KU Leuven, Department of Microbiology, Immunology and Transplantation, Rega Institute for Medical Research, Laboratory of Virology and Chemotherapy, Herestraat 49, 3000, Leuven, Belgium.

Here, we report on the anti-SARS-CoV-2 activity of PRO-2000, a sulfonated polyanionic compound. In Vero cells infected with the Wuhan, alpha, beta, delta or omicron variant, PRO-2000 displayed EC values of 1.1 μM, 2.

View Article and Find Full Text PDF

In order to significantly reduce the computing time while, at the same time, keeping the accuracy and precision when determining the local values of the density and effective atomic number necessary for identifying various organic material, including explosives and narcotics, a specialized multi-stage procedure based on a multi-energy computed tomography investigation within the 20-160 keV domain was elaborated. It consisted of a compensation for beam hardening and other non-linear effects that affect the energy dependency of the linear attenuation coefficient (LAC) in the chosen energy domain, followed by a 3D fast reconstruction algorithm capable of reconstructing the local LAC values for 64 energy values from 19.8 to 158.

View Article and Find Full Text PDF

Photon counting imaging detectors (PCD) has paved the way for spectral x-ray computed tomography (spectral CT), which simultaneously measures a sample's linear attenuation coefficient (LAC) at multiple energies. However, cadmium telluride (CdTe)-based PCDs working under high flux suffer from detector effects, such as charge sharing and photon pileup. These effects result in the severe spectral distortions of the measured spectra and significant deviation of the extracted LACs from the reference attenuation curve.

View Article and Find Full Text PDF

Background: Interpretation of clinical trial results testing vaginal microbicide gels for HIV prevention depends on participant adherence. Prior to the era of antiretrovirals, microbicide trials collected adherence data via self-report, and trials typically reported trial population adherence as overall averages in primary results manuscripts. This study first sought to determine if different patterns of adherence from three trials of vaginal microbicide gels could be identified, using self-reported data and if so, how those patterns compare across trials.

View Article and Find Full Text PDF

In this study, an application of the laser-melting deposition additive manufacturing technique as a welding method has been studied for the laser welding (LW) of AISI 304 stainless steel, specifically 0.4 mm and 0.5 mm thick sheets.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!