High temporal resolution for multislice helical computed tomography.

Med Phys

Medical Systems Research and Development Center, Medical Systems Company, Toshiba Corporation, Tochigi, Japan.

Published: May 2000

Multislice helical computed tomography (CT) substantially reduces scanning time. However, the temporal resolution of individual images is still insufficient for imaging rapidly moving organs such as the heart and adjacent pulmonary vessels. It may, in some cases, be worse than with current single-slice helical CT. The purpose of this study is to describe a novel image reconstruction algorithm to improve temporal resolution in multislice helical CT, and to evaluate its performance against existing algorithms. The proposed image reconstruction algorithm uses helical interpolation followed by data weighting based on the acquisition time. The temporal resolution, the longitudinal (z-axis) spatial resolution, the image noise, and the in-plane image artifacts created by a moving phantom were compared with those from the basic multislice helical reconstruction (helical filter interpolation, HFI) algorithm and the basic single-slice helical reconstruction algorithm (180 degrees linear interpolation, 180LI) using computer simulations. Computer simulation results were verified with CT examinations of the heart and lung vasculature using a 0.5 second multislice scanner. The temporal resolution of HFI algorithm varies from 0.28 and 0.86 s, depending on helical pitch. The proposed method improves the resolution to a constant value of 0.29 s, independent of pitch, allowing moving objects to be imaged with reduced blurring or motion artifacts. The spatial (z) resolution was slightly worse than with the HFI algorithm; the image noise was worse than with the HFI algorithm but was comparable to axial (step-and-shoot) CT. The proposed method provided sharp images of the moving objects, portraying the anatomy accurately. The proposed algorithm for multislice helical CT allowed us to obtain CT images with high temporal resolution. It may improve the image quality of clinical cardiac, lung, and vascular CT imaging.

Download full-text PDF

Source
http://dx.doi.org/10.1118/1.598951DOI Listing

Publication Analysis

Top Keywords

temporal resolution
24
multislice helical
20
hfi algorithm
16
reconstruction algorithm
12
helical
10
resolution
9
high temporal
8
resolution multislice
8
helical computed
8
computed tomography
8

Similar Publications

Understanding ferroelectric domain wall dynamics at the nanoscale across a broad range of timescales requires measuring domain wall position under different applied electric fields. The success of piezoresponse force microscopy (PFM) as a tool to apply local electric fields at different positions and imaging their changing position, together with the information obtained from associated switching spectroscopies has fueled numerous studies of the dynamics of ferroelectric domains to determine the impact of intrinsic parameters such as crystalline order, defects and pinning centers, as well as boundary conditions such as environment. However, the investigation of sub-coercive reversible domain wall vibrational modes requires the development of new tools that enable visualizing domain wall motion under varying applied fields with high temporal and spatial resolution while also accounting for spurious electrostatic effects.

View Article and Find Full Text PDF

A challenge in neuroimaging is acquiring frame sequences at high temporal resolution from the largest possible number of pixels. Measuring 1%-10% fluorescence changes normally requires 12-bit or higher bit depth, constraining the frame size allowing imaging in the kHz range. We resolved Ca or membrane potential signals from cell populations or single neurons in brain slices by acquiring fluorescence at 8-bit depth and by binning pixels offline, achieving unprecedented frame sizes at kHz rates.

View Article and Find Full Text PDF

Background: Apolipoprotein ε4 allele (APOE4) is the strongest genetic risk factor for late-onset Alzheimer's disease (AD) with females having higher risk than males. Compared with non-carriers, cognitively normal, middle-aged APOE4 carriers have lower cerebral blood flow (CBF) decades before clinical symptoms appear. Early intervention to protect CBF would be critical for APOE4 carriers to mitigate AD progression.

View Article and Find Full Text PDF

Background: Alzheimer's disease is a common neurodegenerative disease that affects the lives of millions of people worldwide. In our study, we aim to evaluate the effectiveness and accuracy of the latest automated brain volume analysis method for GM and WM analysis in health control and patients with AD and to compare optimized cut-off values for both regions between subjects.

Method: The original baseline scans from 37 HC (HC) and 39 mild AD patients downloaded from ADNI.

View Article and Find Full Text PDF

Background: Tau pathology accumulates early in the basal forebrain (BF) in Alzheimer's disease (AD). The feasibility of measuring in vivo BF tau is unclear given PET resolution and possible partial volume effects of off-target signal (OTS) which varies by tracer.

Method: We compared measurements of tau in cognitively unimpaired older adults with either an FTP or MK6240 scan: 93 FTP scans from the Berkeley Aging Cohort Study (BACS), 424 FTP scans from ADNI (N=517 FTP scans; 72.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!