International transmission of tele-ophthalmology images.

J Telemed Telecare

Centre for Ophthalmology and Visual Science, University of Western Australia, Australia.

Published: June 2000

Tele-ophthalmic consultations were conducted between a hospital in East Java, Indonesia, and an ophthalmology centre in Perth, Western Australia. Twenty-two eyes of 14 subjects were screened for glaucoma using a hand-held fundus camera. Optic disc images comprised 267 x 234 pixels at 24 bit/pixel (187 kByte). The images were compressed and stored together with patient information on a laptop computer. The images were then transmitted to Perth using either a mobile phone or a satellite phone, taking 170 s or 240 s, respectively. Images were also compressed to five different compression levels before transmission. At a compression ratio of 1:5, the images were 36 kByte in size and took 29 s to transmit by mobile phone and 60 s by satellite phone. To measure the loss of quality, the root mean square error was calculated for each colour component, comparing the transmitted and original images. The coefficients of variation were 10% (green), 15% (blue) and 22% (red). The images received in Perth were considered to be of excellent quality and readily interpreted by ophthalmologists in terms of the likely presence of glaucoma.

Download full-text PDF

Source
http://dx.doi.org/10.1258/1357633001933934DOI Listing

Publication Analysis

Top Keywords

images
8
images compressed
8
mobile phone
8
phone satellite
8
satellite phone
8
international transmission
4
transmission tele-ophthalmology
4
tele-ophthalmology images
4
images tele-ophthalmic
4
tele-ophthalmic consultations
4

Similar Publications

Deep Equilibrium Unfolding Learning for Noise Estimation and Removal in Optical Molecular Imaging.

Comput Med Imaging Graph

January 2025

CAS Key Laboratory of Molecular Imaging, Institute of Automation, Chinese Academy of Sciences, Beijing 100190, China; School of Artificial Intelligence, University of Chinese Academy of Sciences, Beijing 100049, China; National Key Laboratory of Kidney Diseases, Beijing 100853, China. Electronic address:

In clinical optical molecular imaging, the need for real-time high frame rates and low excitation doses to ensure patient safety inherently increases susceptibility to detection noise. Faced with the challenge of image degradation caused by severe noise, image denoising is essential for mitigating the trade-off between acquisition cost and image quality. However, prevailing deep learning methods exhibit uncontrollable and suboptimal performance with limited interpretability, primarily due to neglecting underlying physical model and frequency information.

View Article and Find Full Text PDF

Feasibility of very low iodine dose aortoiliac CT angiography using dual-source photon-counting detector CT.

Eur J Radiol

January 2025

Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:

Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.

Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.

View Article and Find Full Text PDF

Jaundice is an indication of hyperbilirubinemia and is caused by derangements in bilirubin metabolism. It is typically apparent when serum bilirubin levels exceed 3 mg/dL and can indicate serious underlying disease of the liver or biliary tract. A comprehensive medical history, review of systems, and physical examination are essential for differentiating potential causes such as alcoholic liver disease, biliary strictures, choledocholithiasis, drug-induced liver injury, hemolysis, or hepatitis.

View Article and Find Full Text PDF

Objective: Many patients with ruptured intracranial aneurysms (RIAs) underrepresented or excluded from previous randomized controlled trials (RCTs) comparing surgery with endovascular treatment (EVT) are still considered for surgical clipping, but the best management of these patients remains unknown.

Methods: The International Subarachnoid Aneurysm Trial-2 was a randomized trial comparing surgical versus EVT of RIAs considered for surgical clipping, despite the results of previous RCTs, and also eligible for EVT. The primary endpoint was death or dependency according to the modified Rankin Scale score (mRS score > 2) at 1 year.

View Article and Find Full Text PDF

Objective: Ventricular shunt insertion is a common procedure in pediatric neurosurgical practice. In many areas of medicine there is a push toward rationalization of healthcare resources and a reduction in low-value tests or procedures. The intraoperative sampling of CSF at the time of shunt insertion is one traditional aspect of care that has not been rigorously evaluated.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!