Changes in geometry and cortical porosity in adult, ovary-intact rabbits after 5 months treatment with LY333334 (hPTH 1-34).

Calcif Tissue Int

Department of Anatomy and Cell Biology, and Orthopedic Surgery, Indiana University School of Medicine, Indianapolis, Indiana 46202, USA.

Published: June 2000

The purpose of this study was to determine if the increased cortical bone porosity induced by intermittently administered parathyroid hormone (PTH) reduces bone strength significantly. Mature ovary-intact New Zealand white rabbits were treated with once daily injections of vehicle, or PTH(1-34), LY333334, at 10 or 40 microg/kg/day for 140 days. Geometry of the femoral midshaft was measured to evaluate changes in the cross-sectional moment of inertia (CSMI). Cortical porosity was measured in the midshaft of the tibia by dividing cortical area into three zones based on equal divisions of cortical diameter: near endocortical (Zone I), near intermediate (Zone II), and near periosteal (Zone III) regions. Total cortical porosity significantly increased after PTH treatment from 1.4% in the controls to 6.3% in the higher dose group, but the location of the new porosities was not randomly distributed. In the controls, porosity of Zones I and II (both 1.7%) was almost twice as much as that of Zone III (0.9%). In the lower dose group, cortical porosity of Zone I (5.5%) and II (1.8%) was greater than in Zone III (0.9%), but these differences were not statistically significant. In the higher dose group, cortical porosity of Zone I (11.5%) and II (6. 1%) significantly increased compared with Zone III (1.4%) (P < 0. 0005). Histomorphometric measurements showed that bone formation rate on both periosteal and endocortical surfaces increased, resulting in increased bone area and cortical area in the higher dose group. A model was developed to evaluate the effect of the changes in geometry and porosity on CSMI in the different zones. This simulation model indicated that CSMI in the higher dose group was significantly greater than in the other two groups, despite the increased porosity. We speculate the reason to be that porosity increased near the endocortical surface, where its mechanical effect is small. This increase was more than offset by apposition of new bone on the periosteal surface. These data suggest that (1) PTH increases cortical porosity in a dose-dependent manner, primarily near endocortical surfaces; (2) because of this nonhomogeneous distribution, the mechanical effect of increased porosity is small; (3) the increased cortical porosity associated with PTH treatment is more than offset by periosteal apposition of new bone, causing an overall increase in the bending rigidity of cortical bone; and (4) these changes cannot be accurately evaluated using noninvasive methods of bone densitometry, which cannot account for the location of bone gain and bone loss.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s002230010091DOI Listing

Publication Analysis

Top Keywords

cortical porosity
28
dose group
20
zone iii
16
higher dose
16
porosity
13
cortical
12
bone
10
increased
9
changes geometry
8
increased cortical
8

Similar Publications

Osteoporosis is the most common bone metabolic unbalance, leading to fragility fractures, which are known to be associated with structural changes in the bone. Cortical bone accounts for 80 % of the skeleton mass and undergoes remodeling throughout life, leading to changes in its thickness and microstructure. Although many studies quantified the different cortical bone structures using CT techniques (3D), they are often realised on a small number of samples.

View Article and Find Full Text PDF

Enhanced porous titanium biofunctionalization based on novel silver nanoparticles and nanohydroxyapatite chitosan coatings.

Int J Biol Macromol

January 2025

Departamento de Química Orgánica y Farmacéutica, Facultad de Farmacia, Universidad de Sevilla, Seville, Spain. Electronic address:

Titanium is widely used for implants however it presents limitations such as infection risk, stress shielding phenomenon, and poor osseointegration. To address these issues, a novel approach was proposed that involves fabricating porous titanium substrates, to reduce implant stiffness, minimizing stress shielding and bone resorption, and applying polymeric coatings to improve bioactivity. Composite coating prepared from chitosan, silver nanoparticles, and nanohydroxyapatite was optimized to enhance antibacterial properties and promote osseointegration.

View Article and Find Full Text PDF

Generating Virtual Bone Scans for the Purpose of Investigating the Effects of Cortical Microstructure.

J Biomech Eng

January 2025

Dr. Carl D. and H. Jane Clay Department of Mechanical Engineering, Ohio Northern University, 525 S. Main St, Ada OH 45810.

Evaluating the contribution of microstructure to overall bone strength is tricky since it is difficult to control changes to pore structure in human or animal samples. We developed an open-source program that can generate three-dimensional models of micron-scale cortical bone. These models can be highly customized with a wide array of variable input parameters to allow for generation of samples with high similarity to CT scans of cortical bone or with specific geometric features.

View Article and Find Full Text PDF

High-resolution microCT analysis of sclerotic subchondral bone beneath bone-on-bone wear grooves in severe osteoarthritis.

Bone

January 2025

Department of Research and Development, Schulthess Klinik, Lengghalde 2, 8008 Zürich, Switzerland. Electronic address:

Osteoarthritis (OA) is associated with sclerosis, a thickening of the subchondral bone plate, yet little is known about bone adaptations around full-thickness cartilage defects in severe knee OA, particularly beneath bone-on-bone wear grooves. This high-resolution micro-computed tomography (microCT) study aimed to quantify subchondral bone microstructure relative to cartilage defect location, distance from the joint space, and groove depth. Ten tibial plateaus with full-thickness cartilage defects were microCT-scanned to determine defect location and size.

View Article and Find Full Text PDF

Patients with radiographic axial spondyloarthritis (r-axSpA) experience a higher prevalence of fragility fractures, though the pathophysiology of osteoporosis associated with this disease remains poorly understood. The objective of this study was to evaluate the histomorphometric data in r-axSpA patients. Male r-axSpA patients up to 55 years old were enrolled in this cross-sectional study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!