A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

First-generation aortic endografts: analysis of explanted Stentor devices from the EUROSTAR Registry. | LitMetric

Purpose: To examine the structure and healing characteristics of chronically implanted Stentor endografts that were explanted due to migration, endoleak, thrombosis, or aneurysm expansion.

Methods: The devices were harvested following reoperation (n = 5) or autopsy (n = 1) with implantation times ranging from 13 to 53 months. Structural modifications to the metal components were examined using radiography, endoscopy, and magnetic resonance imaging (MRI). Specimens taken from components of the modular stent-grafts were examined histologically and with scanning electron microscopy (SEM) to assess healing behavior. Physical and chemical stability of the nitinol wires and woven polyester graft material was evaluated using SEM and electron spectroscopy for chemical analysis.

Results: Although the endografts were retrieved for a variety of reasons, they exhibited similar healing and structural modifications. The woven polyester sleeve showed evidence of yarn shifting and distortion, yarn damage, and filament breakage leading to the formation of openings in the fabric. The luminal surface endografts showed incomplete healing characterized by a poorly organized, nonadherent thrombotic matrix of variable thickness. Radiographic and endoscopic observations indicated that structural failure of the grafts, particularly in the main aortic component, was related to severe compaction and dislocation of the metallic frame due to suture breaks. Corrosion marks were observed on some nitinol wires in all devices. Chemical analysis and ion bombardment of the nitinol wires revealed that the surface concentrations of titanium and nickel were not homogenous. The first layer was composed of carbon or organic elements, followed by a stratum of highly oxidized titanium with a low nickel concentration; the titanium-nickel alloy lay beneath these layers.

Conclusions: Although the materials selected for construction of endovascular grafts appears judicious, the assembly of these biomaterials into various interrelated structures within the device requires further improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1177/152660280000700205DOI Listing

Publication Analysis

Top Keywords

nitinol wires
12
structural modifications
8
woven polyester
8
first-generation aortic
4
endografts
4
aortic endografts
4
endografts analysis
4
analysis explanted
4
explanted stentor
4
stentor devices
4