Doppler derived systolic pressure gradients have become widely applied as noninvasively obtained estimates of the severity of aortic valvar stenosis. There is little correlation, however, between the Doppler derived peak instantaneous gradient and the peak-to-peak gradient obtained at catheterisation, the latter being the most applied variable to determine severity in children. The purpose of this study was to validate a mathematical model based on data from catheterisation which estimates the peak-to-peak gradient from variables which can be obtained by noninvasive means (Doppler derived mean gradient and pulse pressure), according to the formula: peak-to-peak systolic gradient = 6.02+/-1.49*(mean gradient)-0.44*(pulse pressure). Simultaneous cardiac catheterization and Doppler studies were performed on 10 patients with congenital aortic valvar stenosis. Correlations between the gradients measured at catheter measured, and those derived by Doppler, were performed using linear regression analysis. The mean gradients correlated well (y = 0.67 x +11.11, r = 0.87, SEE = 6 mm Hg, p = 0.001). The gradients predicted by the formula also correlated well with the peak-to-peak gradients measured at catheter (y = 0.66 x +14.44, r = 0.84, SEE = 9 mm Hg, p = 0.002). The data support the application of the model, allowing noninvasive prediction of the peak-to-peak gradient across the aortic valvar stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1017/s1047951100006569DOI Listing

Publication Analysis

Top Keywords

peak-to-peak gradient
16
doppler derived
12
aortic valvar
12
valvar stenosis
12
mathematical model
8
gradients measured
8
measured catheter
8
correlated well
8
gradient
7
peak-to-peak
6

Similar Publications

Background: The pressure gradient between the ventricles and the subarachnoid space (transmantle pressure) is crucial for understanding CSF circulation and the pathogenesis of certain neurodegenerative diseases. This pressure can be approximated by the pressure difference across the aqueduct (ΔP). Currently, no dedicated platform exists for quantifying ΔP, and no research has been conducted on the impact of breathing on ΔP.

View Article and Find Full Text PDF
Article Synopsis
  • The study investigates the double-balloon technique's effectiveness in reducing aortic regurgitation (AR) after balloon aortic valvotomy (BAV) in children, with a focus on short- and mid-term outcomes.
  • Out of 50 patients (average age 6.5 years), 34% had prior AR, and after the procedure, there was a significant decrease in peak-to-peak gradient and only 20% experienced trivial AR post-BAV, while none had severe AR.
  • The technique was found to be safe, with no deaths or emergency surgeries required, suggesting it could be a promising alternative for larger patients, although further long-term studies are needed.
View Article and Find Full Text PDF

Agreement of echocardiographic and catheterization-based methods of transpulmonary pressure gradient measurement in dogs.

J Vet Cardiol

December 2024

Department of Small Animal Medicine and Surgery, College of Veterinary Medicine, University of Georgia, 2200 College Station Rd, Athens, GA 30602, USA.

Article Synopsis
  • The study investigates how well Doppler echocardiographic methods for estimating transpulmonary pressure gradients (PG) in dogs with pulmonary valve stenosis correlate with direct measurements from catheterization.
  • It includes client-owned dogs that underwent balloon pulmonary valvuloplasty, examining echocardiographic data compared to catheterization reports over a 10-year period.
  • The findings show that the echocardiographic methods can lead to systematic errors in PG estimations, with mean PG underestimating and peak PG overestimating the actual pressure gradient, highlighting they are not interchangeable.
View Article and Find Full Text PDF

Background: Cardiac applications in radiation therapy are rapidly expanding including magnetic resonance guided radiation therapy (MRgRT) for real-time gating for targeting and avoidance near the heart or treating ventricular tachycardia (VT).

Purpose: This work describes the development and implementation of a novel multi-modality and magnetic resonance (MR)-compatible cardiac phantom.

Methods: The patient-informed 3D model was derived from manual contouring of a contrast-enhanced Coronary Computed Tomography Angiography scan, exported as a Stereolithography model, then post-processed to simulate female heart with an average volume.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!