A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Estimation of individual sennosides in plant materials and marketed formulations by an HPTLC method. | LitMetric

Senna is a well-known drug, used in the Ayurvedic and Allopathic systems of medicine, and is a treatment for constipation. The purgative action of senna and its formulations is due to the presence of sennosides A and B. An HPTLC method has been developed for the determination of individual sennosides (A, B, C, D) without any derivatization in marketed formulations (three tablet formulations, two granule formulations and one liquid formulation) and plant materials (senna leaf and pod). The methanolic solution of a sample was applied on a pre-coated silica gel G60 F254 TLC plate (E. Merck.) and was developed using n-propanol : ethyl acetate : water : glacial acetic acid (3 : 3 : 2 : 0.1 v/v) as the mobile phase. The relative band speeds (Rf values) obtained were 0.35, 0.25, 0.61, 0.46 for sennosides A, B, C and D, respectively. The densitometric response was monitored at 366nm. Calibration curves were found to be linear in the concentration ranges 193-1356, 402-2817, 71-497 and 132-927 ng per spot for sennosides A, B, C, and D, respectively. The correlation coefficients were found to be 0.9978, 0.9987, 0.9939 and 0.9983 respectively for sennosides A, B, C and D. The result obtained with the HPTLC method for total sennoside content was compared with the results using the pharmacopoeial methods (spectrophotometric (British Pharmacopoeia) and spectrofluorimetric (United States Pharmacopeia) using the 'F' test). The results revealed no significant difference in the three different methods for estimation of total sennoside. The proposed HPTLC method was found to be simple, specific, precise, accurate and rapid. It can be used for routine quality control of sennosides or senna-containing formulations for individual sennosides.

Download full-text PDF

Source
http://dx.doi.org/10.1211/0022357001774066DOI Listing

Publication Analysis

Top Keywords

hptlc method
16
individual sennosides
12
sennosides
8
plant materials
8
marketed formulations
8
total sennoside
8
formulations
6
estimation individual
4
sennosides plant
4
materials marketed
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!