[Lesions of peripheral structures of cadaver fingers caused by Kirschner wires].

Unfallchirurg

Abteilung für Chirurgie, Heeresspital Wien.

Published: March 2000

Fractures of the hand skeleton are common injuries. These are or are associated with phalangeal fractures. Kirschner wires can be used for osteosynthesis, but can cause lesions of peripheral finger structures. The aim of our study was to record the incidence of lesions in peripheral structures of the fingers caused by retrograde crossed inserted Kirschner wires of 1.0, 1.25, 1.4 and 1.6 mm diameter into the middle and proximal phalanges of the long fingers and the proximal phalanx of the thumb of 120 fresh cadaver hands. We found an increase of insertion attempt frequency and an increasing number of lesions with increasing Kirschner wire diameter. Because of these findings Kirschner wires of 1.0 or 1.25 mm diameter should be preferred to prevent the peripheral functional finger structures.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s001130050523DOI Listing

Publication Analysis

Top Keywords

kirschner wires
12
peripheral structures
8
fingers caused
8
lesions peripheral
8
finger structures
8
wires 125
8
125 diameter
8
kirschner
5
[lesions peripheral
4
structures
4

Similar Publications

Background: Untreated cubitus varus results in cosmetic deformity as well as posterolateral rotatory instability at the elbow if longstanding. French osteotomy with its modifications is the most commonly done osteotomy and relies on a medial intact hinge and these osteotomies fail to address the lateral prominence. Intraoperative fixator assistance to adjust the translation and fine tune the osteotomy is a novel method to address the lateral prominence.

View Article and Find Full Text PDF

Hook plate fixation and tension band wiring in the treatment of Mayo type II olecranon fractures.

J Orthop Surg Res

January 2025

Department of Orthopedic Trauma, Beijing Jishuitan Hospital, Capital Medical University, No. 31 Xinjiekou East Street, Xicheng District, Beijing, 100035, China.

Background: Olecranon fractures account for 8 ∼ 10% of all elbow fractures and usually require surgical intervention. Tension band wiring (TBW) is considered as the standard treatment while it is associated with high re-operation rates.

Objective: This study aims to compare the functional outcomes, complications and re-operations of hook plate fixation (HPF) versus TBW in treating Mayo Type II olecranon fractures.

View Article and Find Full Text PDF

Background: The aim of study was to biomechanically compare the fixation of Jones fracture using headless cannulated screw, tension band, and two Kirschner wires.

Methods: A total of 60 fourth-generation, fifth metatarsal synthetic bone models were divided into three groups according to the fixation techniques. A vertical load, oriented from plantar to dorsal and lateral to medial, was applied to the metatarsal specimen that were potted with molding material.

View Article and Find Full Text PDF

Background: Management of the extensive soft tissue injuries remains a significant challenge in orthopedic and plastic reconstructive surgery. Since the thumb is responsible for 40% of the functions of the hand, saving and reconstructing a mangled thumb is essential for the patient's future.

Case Presentation: This case report describes the management of a severe occupational thumb injury in a 25-year-old white Persian male who sustained an occupational injury to his left thumb, resulting in extensive burn, crush injury to the distal and proximal phalanx, and severe soft tissue damage to the first metacarpal, thenar, and palmar areas.

View Article and Find Full Text PDF

The study aimed to evaluate a newly designed semicircular implant for the fixation of Vancouver Type B1 periprosthetic femoral fractures (PFFs) in total hip arthroplasty (THA) patients. To determine its strength and clinical applicability, the new implant was compared biomechanically with conventional fixation methods, such as lateral locking plate fixation and a plate combined with cerclage wires. : Fifteen synthetic femur models were used in this biomechanical study.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!