This study was undertaken to develop and test a morphology-based adaptive algorithm for real-time detection of P waves and far-field R waves (FFRWs) in pacemaker patient atrial electrograms. Cardiac event discrimination in right atrial electrograms has been a problem resulting in improper atrial sensing in implantable devices; potentially requiring clinical evaluation and device reprogramming. A morphology-based adaptive algorithm was first evaluated with electrograms recorded from 25 dual chamber pacemaker implant patients. A digital signal processing (DSP) system was designed to implement the algorithm and test real-time detection. In the second phase, the DSP implementation was evaluated in 13 patients. Atrial and ventricular electrograms were processed in real-time following algorithm training performed in the first few seconds for each patient. Electrograms were later manually annotated for comparative analysis. The sensitivity for FFRW detection in the atrial electrogram during off-line analysis was 92.5% (+/- 10.9) and the positive predictive value was 99.1% (+/- 1.8). Real-time P wave detection using a DSP system had a sensitivity of 98.9% (+/- 1.3) and a positive predictivity of 97.3% (+/- 3.5). FFRW detection had a sensitivity of 91.0% (+/- 12.4) and a positive predictivity of 97.1% (+/- 4.2) in atrial electrograms. DSP algorithm tested can accurately detect both P waves and FFRWs in right atrium real-time. Advanced signal processing techniques can be applied to arrhythmia detection and may eventually improve detection, reduce clinician interventions, and improve unipolar and bipolar lead sensing.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1540-8159.2000.tb00823.xDOI Listing

Publication Analysis

Top Keywords

atrial electrograms
16
detection
8
wave detection
8
pacemaker patient
8
patient atrial
8
morphology-based adaptive
8
adaptive algorithm
8
real-time detection
8
waves ffrws
8
signal processing
8

Similar Publications

Background: Current outcomes from catheter ablation for scar-dependent ventricular tachycardia (VT) are limited by high recurrence rates and long procedure durations. Personalized heart digital twin technology presents a noninvasive method of predicting critical substrate in VT, and its integration into clinical VT ablation offers a promising solution. The accuracy of the predictions of digital twins to detect invasive substrate abnormalities is unknown.

View Article and Find Full Text PDF

Pulsed Field Ablation (PFA) is a new ablation method being rapidly adopted for treatment of atrial fibrillation, which shows advantages in safety and efficiency over radiofrequency and cryo-ablation. In this study, we used an in vivo swine model (10 healthy and 5 with chronic myocardial infarct) for ventricular PFA, collecting intracardiac electrograms, electro-anatomical maps, native T1-weighted and late gadolinium enhancement MRI, gross pathology, and histology. We used 1000-1500 V pulses, with 1-16 pulse trains to vary PFA dose.

View Article and Find Full Text PDF

Premature ventricular contractions (PVCs) are a common finding in patients with surgically repaired congenital heart defects including transposition of the great arteries (D-TGA). While often asymptomatic, PVCs can sometimes lead to palpitations, dyspnea, and hemodynamic compromise, requiring therapeutic intervention. The arterial switch operation is the preferred treatment for D-TGA, but these patients have a 2% incidence of ventricular arrhythmias and 1% incidence of sudden cardiac death post-operatively.

View Article and Find Full Text PDF

In 1924, the Dutch physiologist Willem Einthoven received the Nobel Prize in Physiology or Medicine for his discovery of the mechanism of the electrocardiogram (ECG). Anno 2024, the ECG is commonly used as a diagnostic tool in cardiology. In the paper 'Le Télécardiogramme', Einthoven described the first recording of the now most common cardiac arrhythmia: atrial fibrillation (AF).

View Article and Find Full Text PDF

Monitoring and modulating cardiac bioelectricity: from Einthoven to end-user.

Europace

December 2024

Laboratory of Experimental Cardiology, Department of Cardiology, Leiden University Medical Center, Albinusdreef 2, Leiden 2333 ZA, The Netherlands.

In 2024, we celebrate the 100th anniversary of Willem Einthoven receiving the Nobel Prize for his discovery of the mechanism of the electrocardiogram (ECG). Building on Einthoven's legacy, electrocardiography allows the monitoring of cardiac bioelectricity through solutions to the so-called forward and inverse problems. These solutions link local cardiac electrical signals with the morphology of the ECG, offering a reversible connection between the heart's electrical activity and its representation on the body surface.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!