The LIAISON immunoassay analyser was tested in a multicentre evaluation performed by 8 laboratories. The analytes evaluated were CA 15-3, CA 19-9, CA 125II, AFP, CEA, NSE and PSA. Excellent results were obtained for within-run and between-run precision with most assays showing within-run CVs < 5% and between-run CVs between 4 and 8%. The linearity of all assays was acceptable, however, for PSA, NSE and CA 19-9 a recovery > 110% was obtained for some of the samples tested. None of the assays revealed a high-dose hook effect. Method comparisons were performed by using the routine method of the respective study centre. Results generally showed an acceptable agreement between the LIAISON system and the different methods of comparison. The reference ranges for all assays were found to be in accordance with data known from the literature. All assays showed similar results for serum, heparinised plasma and EDTA plasma. Additionally, two experiments were performed with only one of the analytes tested: the sample-to-sample carry-over, using the CA 19-9 assay (3.3 x 10(-6)-2.3 x 10(-5)) and the functional sensitivity for the PSA assay (0.2 ng/ml).
Download full-text PDF |
Source |
---|
Heliyon
December 2024
Microbiology Department, Clinical Laboratory North Metropolitan Area, Germans Trias I Pujol University Hospital, 08916 Badalona, Spain.
Background And Objective: Serological screening for Chagas disease (CD) in Latin American adults living in Europe is a cost-effective strategy for transmission prevention. The World Health Organization recommends two different serological tests including native and recombinant antigens for IgG detection. In Spain, most commercialized native tests require manual processing.
View Article and Find Full Text PDFClin Chem Lab Med
December 2024
Bioanalytical Facility, Norwich Medical School, University of East Anglia, Norwich, UK.
Objectives: Automated immunoassays for 1,25-dihydroxyvitamin D (1,25(OH)D) have increased the use of serum measurements in clinical and research settings, but disagreement with LC-MS/MS methods remains an issue.
Methods: In this study, we examined this problem using samples obtained from healthy young adults, n=80, mean age 21.7 (18-32) years, and a large cohort of paediatric samples, n=422, mean age 7.
Steroids
January 2025
Department of Endocrinology, The First Affiliated Hospital of Chongqing Medical University, Chongqing, China.
Purpose: Compared with chemiluminescence immunoassay (CLIA), the quantification of the plasma aldosterone concentration (PAC) via liquid chromatography-tandem mass spectrometry (LC-MS/MS) yields lower values. The extent to which this difference is exacerbated by a reduced glomerular filtration rate (eGFR) is unclear. Therefore, this study aims to assess the impact of renal insufficiency on PAC as measured by CLIA using LC-MS/MS as the reference method.
View Article and Find Full Text PDFJ Immunoassay Immunochem
January 2025
Interdisciplinary Department of Medicine, Aldo Moro University, Bari, Italy.
Our study evaluated the possible interference of Burosumab (human recombinant monoclonal antibody directed against N-terminal domain of FGF23) on the immunoassay of intact FGF23 (iFGF23) with the Liaison XL. The analytical method uses three different antibodies, one of which directed against the N-terminal portion of FGF23. The evaluation of the method accuracy involved the fully automated execution of a dilution test on EDTA plasma from 5 subjects who had not received any monoclonal antibody (mAb), 20 EDTA plasma from patients treated with Burosumab, and 2 EDTA plasma from subjects who had not received any mAb in witch an adequate volume of Burosumab had been added in vitro.
View Article and Find Full Text PDFJ Med Virol
November 2024
Laboratoire de Virologie, INSERM, Institut Pierre Louis d' Epidémiologie et de Santé Publique, AP-HP, Hôpitaux Universitaires Pitié Salpêtrière-Charles Foix, Sorbonne Université, Paris, France.